4. MANTEL CLEARANCES
If the mantel shelf on your masonry fireplace is of a combustible material the
minimum distance from the floor protector is as follows. This may be reduced if a
Firenzo Kompact Deflector is fitted.
A Unprotected B With Firenzo Deflector
Kompact Forte 975mm 915mm
Kompact Athena 1100mm 915mm
Kompact Deco 1225mm 915mm
SIDE PILLAR CLEARANCE
The minimum clearance from the side of the fascia to any heat sensitive material
must be 5mm providing the material does NOT protrude more than 150mm.
UNPROTECTED MANTEL
MINIMUM CLEARANCE
FIRENZO HEAT
DEFLECTOR FITTED
DEFLECTOR
A B
Diagram 3