FO2 - On: this option will enable the anti-carjacking feature. Make sure the starter interrupt relay is
wired to interrupt the vehicle’s ignition wire, so the feature will operate as described. While the vehicle
is running with the key and the panic mode is activated using any Firstech 4 button or 2-way
LCD
remote, the CMX
will
enable the ignition interrupt relay so the vehicle cannot be
re-
started.
Note:
When using
ignition-kill
on manual transmission vehicles feature 3-04 must be set to
option
2
will
need to be utilized. this disables the anti-grind circuit while the vehicle is remote-started; if
the
anti-
grind circuit is active and the
start-kill
relay is installed in the ignition, the relay
will
“buzz” while
remote-
started.
3-06 Security Features: This feature will enable or disable the security or remote start features of the CMX.
Security features include sensor inputs, monitoring zone inputs while armed, horn, and siren output. Basic
features will function normally (lock, unlock, trunk release, remote start, parking lights.)
FO1 – Off (default): This option disables the security features of the CMX allowing it to operate as a
remote start only control module.
FO2 - On: This option enables the security features of the CMX allowing it to operate as a remote start
and security control module.
FO3 – Alarm Only: This option will disable the remote start function of the CMX allowing it to
operate as security only control module.
3-07 Siren Duration: this feature changes the duration of the siren during full alarm.
FO1 - 30 seconds: this option will provide 30 seconds of output (+) on the siren wire (brown CN5)
during full alarm.
FO2 - 60 seconds: this option will provide 60 seconds of output (+) on the siren wire (brown CN5)
during full alarm.
FO3 - 120 seconds: this option will provide 120 seconds of output (+) on the siren wire (brown
CN5) during full alarm.
FO4 - Chirps for 20 seconds: this option will provide 20 seconds of pulsed output (+) on the siren
wire (brown CN5) during full alarm.
3-08 Horn output: This feature controls the horn output behavior during Arm, Disarm, and Remote Start.
(POC 2 White wire or POC setting #8)
FO1 - On double lock only: (default) this option is designed to simulate a factory keyless entry system
by providing a horn output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first lock command.
FO2 - On lock and Unlock only: this option will provide a horn output pulse (based on the option
selection of feature 3-02) with each lock or unlock confirmation.
FO3 - On lock, Unlock, and Start: this option will provide a horn output pulse (based on the option
selection of feature 3-02) with each lock, unlock, remote start command and remote started
confirmation.
FO4 - On double lock and Start: this option is designed to simulate a factory keyless entry system by
providing a horn output pulse (based on the option selection of feature 3-02) each time the lock
command is sent a second time within 8 seconds of the first. In addition, it will provide a horn output
pulse with remote start command and remote started confirmation.