3-12 VAC: (thermistor required) this determines the temperature at which the CMX will provide an output on
any POC programmed with setting 22(VAC: Ventilation-Air Conditioning) which can be used to vent
widows, activate AC controls, or cooling seats.
FO1 - 100°F: This option will provide a pulsed output on any POC programmed with setting 22
(VAC) if the temp sensor reads at or above 100°F with remote start confirmation.
FO2 - 90°F: This option will provide a pulsed output on any POC programmed with setting 22 (VAC)
if the temp sensor reads at or above 90°F with remote start confirmation.
FO3 - 80°F: This option will provide a pulsed output on any POC programmed with setting 22 (VAC)
if the temp sensor reads at or above 80°F with remote start confirmation.
FO4 - 90°F: Latched output: this option will provide a latched output for the selected runtime on any
POC programmed with setting 22 (VAC) if the temp sensor reads at or above 90°F.
3-13 Defrost output Temperature Control: This feature will determine the temperature at which the CMX
will provide an output on any POC programmed with setting 17 or 21 (defrost and defrost 2).
FO1 – Standard (activate with every start): (Default) this option will provide an output (length of
output based on feature 3-13 option settings) on any POC programmed with setting 17 (defrost) or 21
(defrost 2) every time with remote start confirmation.
FO2 - 32°F: (thermistor required) this option will provide an output on any POC programmed with
setting 17 (defrost) or 21 (defrost 2) with remote start confirmation on. This will happen if the temp
reading is at or below 32°F. (Length of output based on feature 3-13 option settings)
FO3 - 42°F (default) PROGRAMMABLE 0°C/32°F ~ 13°C/55°F: (thermistor required) this option will
provide an output on any POC programmed with setting 17 (defrost) or 21 (defrost 2) with remote start
confirmation on. This will happen if the temp reading is at or below 42°F (default temp) but can be
programmed up to 55°F (using the OP500 programmer with software v.30 or newer)
(Length of output for POC setting 17, based on feature 3-13 option settings)
FO4 – AUX 1: This option will allow the user to activate/deactivate the Defrost outputs using the AUX
1 function from any Firstech remote or Drone. NOTE: This feature does not use an AUX output
3-14 Defrost output Timing: This feature controls the output timing of POC setting 17, defrost. Note: POC
setting 21 defrost 2 is has a fixed pulsed output and is NOT affected by this feature.
FO1 - 500mS Pulse: This option will provide a 500 Millisecond pulsed output on any POC
programmed with setting 17 (Defrost) with timing based off feature 3-12 option setting.
FO2 - 3 minute latched: This option will provide a 3-minute latched output on any POC
programmed with setting 17 (Defrost) with timing based off feature 3-12 option setting. (This would be
good for any rear-view mirror defrost that may need a short-latched output time.)
FO3 - 7 minute latched: This option will provide a 7-minute latched output on any POC
programmed with setting 17 (Defrost) with timing based off feature 3-12 option settings. (This
would be good for many front, rear, or rear-view mirror defrost functions that may need a longer
latched output time.)
FO4 - Latched for entire runtime: (Remote start runtime based off feature 2-07 option setting) This
feature will provide a latched output for the entire remote start runtime on any POC programmed with
setting 17 (defrost) with timing based off feature 3-12 option settings. Caution: make sure not to latch
rear defrost functions on for too long as it may cause damage to the heating elements in the window.