https://
install.myfirstech.com
Copyright 2020 Fi rste ch, LLC. “Hello, my name is Inigo Montoya....” Page
57
4-14 Low battery warning: This feature offers low battery options to help alert the user of a low battery in the
vehicle while the CM is locked/armed.
FO1 - On: This option will provide an alert to any Firstech 2 Way LCD remote or Drone when the
vehicle’s battery voltage (at the CMX power connector) drops to 11.7volts. Note: the Firstech 2-way
LCD remote must be within range of the vehicle to receive the low battery alert and this option must be
set to receive low battery alerts to Drone.
FO2 - On + Start: This option will provide an alert to any Firstech 2 Way LCD remote or Drone when
the vehicles battery voltage (at the CMX power connector) drops to 11.7volts. In addition to the alert
the user can active the Timer mode (please refer to this manual for timer mode feature description) to
enable the low battery start function. Once the timer mode is active the CMX will adhere to the timer
mode feature options selected but also monitor the vehicle battery voltage which will override the timer
mode and start at 11.7 volts.
FO3 – OFF: This option disables the low battery alert.
4-15 KP2 Sensitivity: This feature will allow the sensitivity for the KP2 keyless entry window sensor to be
adjusted to suit the conditions.
FO1 – Normal (default): This will be the standard sensitivity setting.
FO2 – High: This option is the most sensitive sensor setting.
FO3 – Low: This option will be lower sensitivity than the default standard setting.
FO4 – Lowest: This option will decrease the sensor sensitivity to its lowest setting.
4-16 Auto Re-Start: This feature will set the CM to re-start the full remote start runtime automatically 10
seconds after the initial runtime has expired, allowing for the user to have runtime extending past the
maximum 45 minutes. NOTE: Once this option is enabled it will re-start every time the runtime is
allowed to time out.
FO1 – Off (default): This option disables the auto re-start feature, providing the standard runtime.
FO2 – ON w/1 re-start: This option will enable the auto re-start function and allow the CM to
automatically re-start and run the full runtime 10 seconds after the first runtime has expired ONLY 1
time. (i.e. 15 minute runtime will expire, pause 10 seconds, re-start and run 15 minutes)
FO3 – ON w/2 re-starts: This option will enable the auto re-start function and allow the CM to
automatically re-start and run the full runtime 10 seconds after the first runtime has expired 2 times for
a total of 3 full runtimes. (i.e. 15 minute runtime will expire, pause 10 seconds, re-start and run 15
minutes, shut down pause 10 seconds, re-start and run for a 3
rd
15 minute runtime)