Special Option Groups 1, 2, 3 and 4
IMPORTANT: The OP500 is required to change settings in Special Option Groups 1 and 2. Special
Option Group 1
SO1- Diesel Timer: (Option 2-03 must first be set to setting 2.) This special option allows a specific
wait to start time (in seconds) to be programmed. This prevents the need for a timer relay and eliminates
a connection to the “wait to start” wire.
SO2 - Aux 1 Output Timing: (Option 4-01 must first be set to setting 4.) This special option allows a
specific output duration for Aux 1 to be programmed 1-99 seconds. Note with OP500 update to software
v.30, latched output time 1-15 minutes are available for programming in addition to the standard 1-99
seconds.
SO3 - Aux 2 Output Timing: (Option 4-02 must first be set to setting 4.) This special option allows a
specific output duration for Aux 2 to be programmed 1-99 seconds. Note with OP500 update to software
v.30, latched output time 1-15 minutes are available for programming in addition to the standard 1-99
seconds.
SO4 - SO8 - Aux 3-7 Output Timing: (Option 3-11 must first be set to setting 2 and the optional
Auxiliary settings module must be used and AUX 3-7 function only available with 2 Way LCD remotes)
These special options allow specific output durations to be set for Aux 3-7. Note with OP500 update to
software v.30, latched output time 1-15 minutes are available for programming in addition to the
standard 1-99 seconds.
SO9- Remote Start Runtime: (Feature 2-07 must first be set to option 4.) This special option allows a
custom Remote start time (in minutes up to 45 minutes) to be programmed. The default runtime is 3
minutes.
SO10- Cold Start Temperature: (Feature 2-08 must first be set to option 4.) This special option allows
a specific temperature (in degrees F or degrees C based on OP500 software update v.30 V1 or V2) to be
set between -30 ~ 0 [°C] / -22 ~ 32 [°F] with a default temperature of -15°C / 5°F default for the Cold
Start Timer mode activation
SO11- Hot Start Temperature: (Feature 2-09 must first be set to option 4.) This special option allows
a specific temperature (in degrees F or degrees C based on OP500 software update v.30 V1 or V2) to
be set between 20°C ~ 40°C / 68°F ~ 104°F with a default temperature of 40°C / 104°F default the Hot
Start Timer Mode activation
SO12- Defrost Temperature: (Feature 3-13 must first be set to option 3.) This special option allows a
specific temperature (in degrees F or degrees C based on OP500 software update v.30 V1 or V2) to be
set between 0°C/32°F ~ 13°C/55°F with a default temperature of 6°C/42°F for the defrost activation
SO13 – Assumed Crank time: when feature 2-10 is set to option 4, the crank time will default to 3
seconds but is adjustable 1-6 seconds in 1 second increments. NOTE: MUST USE AN OP500
UPDATED WITH OP500v.31 AND UP. This firmware and updating process can be found at
Firstechdata.com
SO14 – N/O Secure Start Output time: When feature 3-17 is set to option 4 the N/O output time will
default to 10 minutes but is adjustable 1-10 minutes in 1-minute increments. NOTE: MUST USE
OP500 UPDATED WITH OP500v.36 AND UP This firmware and updating process can be found at
Firstechdata.com