Special Option Group 2
This special option group allows you to select the output setting of the Programmable Output Channel (POC)
wire. For example, if you want to set POC #5 (default setting status out with setting value of 0) to Aux 1, you
will need change special option 5 to setting value 10. This must be done with the OP500.
POC 1 - Blue/White • Starter Kill (starter interrupt/Anti-grind): (default setting value 0) This
channel will provide a 250mA (-) negative output when the CMX is armed (function also POC
setting 29)
POC 2 - White • Horn: (default setting value 0) This channel will provide a 250mA output when
Horn is triggered. (function also POC setting 8)
POC 3 - Blue/Black • Lock: (default setting value 0) This channel will provide a 250mA output with
the lock/arm command. (function also POC setting 25)
POC 4 - Blue • Unlock: (default setting value 0) This channel will provide a 250mA output with
the unlock/disarm command. (function also POC setting 26)
POC 5 - Orange/White • FAD (Factory Alarm Disarm): (default setting value 0) This channel will
provide a 250mA output with the unlock/disarm command. Note: the CMX will provide this
output approx. 100mS before the unlock output. (function also POC setting 7)
POC 6 - Orange • FAA (Factory Alarm Arm): (default setting value 0) This channel will provide a
250mA output with the lock/arm command. Note: the CMX will provide this output approx.
100mS before the unlock output. (function also POC setting 6)
POC 7 - Violet/White • Trunk release: (default setting value 0) This channel will provide a 250mA
output with the trunk release command. (function also POC setting 28)
POC 8 - Black • GWR (ground when running aka status output): (default setting value 0) This
channel will provide a 250mA output with the remote start activation command and
continue to provide output until 100mS after the remote start process has shut own.
(function also POC setting 5)
POC setting value description (SV)
SV 0 – DEFAULT SETTING by wire
SV 1 - Parking light: provides a 250mA (-) negative parking light output on any POC programmed with
this setting.
SV 2 - Starter: provides a 250mA (-) negative starter output on any POC programmed with this
setting.
SV 3 - Ignition: provides a 250mA (-) negative ignition output on any POC programmed with this
setting.
SV 4 - Accessory: provides a 250mA (-) negative accessory output on any POC programmed with this
setting.
SV 5 - GWR (status): provides a 250mA (-) negative while remote started on any POC programmed with
this setting. Can be used to activate interface modules during the remote start process.
SV 6 - FAA (Factory Alarm Arm): provides a 250mA, 800mS (-) negative output with the arm/lock
command on any POC programmed with this setting.
SV 7 - FAD (Factory Alarm Disarm): provides a 250mA, 800mS (-) negative output with the
disarm/unlock command on any POC programmed with this setting.