SV 8 - Horn: provides a 250mA (-) negative output with output control based on feature 3-08 option
setting when using any POC programmed with this setting.
SV 9 - Dome light supervision: provides a 250mA (-) negative output with the disarm/unlock command,
on any POC programmed with this setting, for up to 45 seconds or until ignition is on.
SV 10 - AUX1: provides a 250mA (-) negative output (based on feature 4-01 setting) when AUX is
triggered by Firstech 4 button remote, 2way LCD remote, or Drone, on any POC
programmed with this setting.
SV 11 - AUX2: provides a 250mA (-) negative output (based on feature 4-02 setting) when AUX is
triggered by Firstech 4 button remote, 2way LCD remote, or Drone, on any POC
programmed with this setting.
SV 12 - AUX3: provides a 250mA (-) negative output (based on AU3 setting) when AUX3 is triggered,
using a Firstech 2-way LCD remote (please refer to remote users guide for activation steps), on
any POC programmed with this setting. (Feature 3-11 must be set to option 2)
SV 13 - AUX4: provides a 250mA (-) negative output (based on AU4 setting) on any POC programmed
with this setting, when AUX4 is triggered using a Firstech 2-way LCD remote (please refer to
remote users guide for activation steps), (Feature 3-11 must be set to option 2)
SV 14 - AUX5: provides a 250mA (-) negative output (based on AU5 setting) on any POC programmed
with this setting, when AUX5 is triggered, using a Firstech 2-way LCD remote (please refer to
remote users guide for activation steps), on any POC programmed with this setting. (Feature 3-
11 must be set to option 2)
SV 15 - AUX6: provides a 250mA (-) negative output (based on AU6 setting) on any POC programmed
with this setting, when AUX6 is triggered, using a Firstech 2-way LCD remote (please refer to
remote users guide for activation steps), on any POC programmed with this setting. (Feature 3-
11 must be set to option 2)
SV 16 - AUX7: provides a 250mA (-) negative output (based on AU7 setting) on any POC
programmed with this setting, using a Firstech 2-way LCD remote (please refer to remote
users guide for activation steps (Feature 3-11 must be set to option 2)
SV 17 - Defrost: provides a 250mA (-) negative output (based on feature 3-13/3-14 settings)on any POC
programmed with this setting,
when defrost function has been activated (output time based on features 3-13 and 3-14
option settings)
SV 18 - GWA (ground While Armed): provides a 250mA (-) negative output on any POC
programmed with this setting, while the system is armed or locked.
SV 19 - GWR 2 (status output 2): provides a 250mA latched (-) negative output on any POC
programmed with this setting, when the remote start sequence is activated and continue until
after the remote start has shut down. Note: With GWR 2 the output will not provide ground during
reservation mode set up to avoid any possible factory immobilizer issue that may occur if the vehicle
sees 2 or more immobilizer override coding.
SV 20 - Siren 2: provides a 250mA latched (-) negative output on any POC programmed with this
setting, only with the full alarm or panic modes. May be used to power any additional horn or
sirens while the CMX is in full alarm or panic mode.
SV 21 - Defrost 2: provides a 250mA (-) negative pulsed output only on any POC programmed with this
setting, when the defrost output is engaged based on the temp setting of feature 3-13.