EasyManua.ls Logo

Firstech CM-X - Page 61

Firstech CM-X
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CMX is t
he
Solution
https://
install.myfirstech.com
CMX
Master
Guide
Copyright 2020 Fi rste ch, LLC. “Hello, my name is Inigo Montoya....” Page
61
SV 22 - VAC (Ventilation and Air Conditioning): provides a 250mA (-) negative output on any POC
programmed with this setting, when the VAC feature is activated based on temperature settings
of feature 3-12 during the remote start sequence.
SV 23 – Hazard Light 2 Control: provides a 250mA (-) negative output on any POC programmed with this
setting that will produce a pulsed output allowing the CM to activate and then deactivate a
latching hazard switch. This will simulate parking light flashes in single flash pulses. This
output will also provide a pulsed parking light output during remote start flashing 1 time
every 10 seconds.
SV 24 - AUX3 w/ RFID unlock: provides a 250mA (-) negative output on any POC programmed with
this setting, (based on timing set for AUX 3) will activate AUX 3 when RFID proximity
unlock has been triggered. Active unlock from a remote or Drone will NOT trigger this AUX 3
output.
SV 25 - Lock: provides a 250mA, 800mS (-) negative output on any POC programmed with this setting,
with the lock/arm command.
SV 26 - Unlock: provides a 250mA, 800mS (-) negative output on any POC programmed with this
setting, with the unlock/disarm command.
SV 27 - 2nd Unlock: provides a 250mA, 800mS (-) negative output on any POC programmed with this
setting, when using the driver’s door priority feature. This wire would be used to unlock the rest
of the doors while unlock should be used to unlock the isolated driver’s door. Note: this output
can only be activated within 7 seconds after the first unlock command is sent.
SV 28 - Trunk release: provides a 250mA, 1 second (-) negative output (output timing based on feature
1-15 on any POC programmed with this setting, with the trunk release command.
SV 29 – Starter Kill: provides a 250mA (-) negative output on any POC programmed with this setting,
while the system is armed or locked, and during remote start for Anti-Grind.
SV 30 – Hazard Light Control: provides a 250mA (-) negative output on any POC programmed with this
setting that will produce a pulsed output allowing the CM to activate and then deactivate a
momentary hazard switch. This will simulate parking light flashes in single flash pulses. This
output will also provide a pulsed parking light output during remote start flashing 1 time
every 10 seconds.
SV 31 – RAP Control: provides a 250mA-800mS (-) negative output on any POC programmed with this
setting that will produce a pulsed output:
-after every remote start shut down (manual, emergency, or runtime timeout)
-after ignition pulse when using feature 1-11 options 2, 3, or 4
Note: there will be no output pulse if ignition is present after remote start take over has been
completed Note: In case of manual transmission the CM will ignore door zone input (analog or
data) ONLY, for the duration of the RAP output pulse.
SV 32 – Secure Start N/O: Provides a 250mA negative timed output that can be used to manage an FTI-
SPTS vehicle PTS button disable harness. It will only output with the selected time (feature 3-17)
when the system is disarmed/unlocked using a Firstech remote, Drone, or KP sensor. It is designed
to enable the vehicle PTS function while it is providing output. Once the output shuts off the
vehicle PTS button will be disabled. If the system times out before the vehicle is started, the
disarm/unlock command must be sent again. Once the system senses Ignition on , it will remain
latched on until Ignition is off. Once ignition is off it will remain latched for the selected time
based on feature 3-18 or until the system is armed/locked using a Firstech remote, Drone, or KP
sensor.