Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2
CM7200 Master Guide
Starter System
techfeed.compustar.com
Copyright 2014 Firstech, LLC. Page 26
Option Group 3
Feature Default Setting - I Optional Setting - II Optional Setting - III Optional Setting - IV
3-01
Parking lights While Remote
Started
Constant Output Flashing Output Off
Off with Lock and
Unlock Only
3-02
Confirmation Chirps Medium (30 ms) Short (15 ms) Normal (60 ms)
3-03
Dome Light Delay Off 5 sec 45 sec Auto
3-04
Starter-Kill Relay
Anti-Grind + Starter
Kill
Anti-Grind
Anti-Grind + Passive
Starter Kill
3-06
Factory Style Alarm Off On
3-08
Horn Output On Double Lock Only On Lock and Unlock
On Lock, Unlock, and
Start
On Double Lock and
Start
3-09
Siren Output
On Lock, Unlock, and
Start
On Double Lock Only On Lock and Unlock
On Double Lock and
Start
3-10
Valet
Brake + Key 5 times
or Remote (Lock +
Trunk) w/Ign. On
Key 5 times or Remote
(Lock + Trunk)
(+)Keysense Input
3-11
Auxiliary Settings Mode Disabled Enabled
3-12
VAC (Ventilation, Air
Conditioning)
Above 100 Degrees F Above 90 Degrees F Above 80 Degrees F
Above 90 Degrees
Latched for Runtime
3-13
Defroster Temperature
Control
Standard
Only below 32
degrees F
Only below 42
degrees F
3-14
Defroster Output Timing 0.5 sec pulse 3 min latch 7 min latch
Constant Output Until
Remote Start Shuts
Down
3-15
Soft Disarm Off On
3-16
RPS FT-RPS Touch FT-RPS 2
Option Group 2
2-06
Timer Start, or, Minimum
Interval Between Cold Starts
3 Hour (4 minute
runtime, double for
Diesel)
2 Hour Repeat with
Cold Starting of 2-08
(Runtime set by 2-07)
2 Way LCD Remotes Only
Reservation (Runtime
set by 2-7) 2 Way LCD
Remotes Only
24 Hour Repeat with
Cold Starting of 2-8
(Runtime set by 2-7) 2
Way LCD Only
2-07
Remote Start Runtime 15 Min 25 Min 45 Min 3 Min
2-08
Temperature of Cold Starting -10° C / 14° F -20° C / -4° F -5° C / 23° F -15° C / 5° F
2-09
Temperature of Hot Starting 25° C / 77° F 30° C / 86° F 35° C / 95° F 40° C / 104° F
2-10
Engine Sensing Tach Alternator
No Connection -
Tachless Sensing
(Automatic Trans Only)
No Connection – 3
Second Crank
(Automatic Trans Only)
2-11
Advanced Tachless Off On
2-12
Crank Time Standard
+0.2 Seconds to
Crank Time
+0.6 Seconds to
Crank Time
(-)0.2 Second Crank
Time
2-13
Timer Mode Off On
2-14
Emergency Brake or Parking
Light Reminder Input
(-) Emergency Brake
Input
(-) Parking Light
Reminder Input
(-) Trigger Start Input