14
GENERAL
Placement of Unit.
Specified clearance maintained to cabinet surfaces.
Unit Level- front to back, side to side.
All packaging material and tie straps removed.
ELECTRICAL:
Receptacle with 15 ampere circuit protection is provided for service cord connection.
Adequate ground connection.
GAS SUPPLY:
Connection: 1/2” NPT flex line with a minimum 5/8” diameter.
The pressure regulator which is connected to the manifold is set for 4.0” W.C. for Natural Gas or 10” W.C.
for LP.
Manual gas shut-off valve installed in an accessible location.
Unit tested and free of gas leaks.
OPERATION:
All internal packing materials are removed, i.e. below grates, around knobs, etc.
Bezels centered on burner knobs and knobs turn freely.
Each burner lights satisfactorily, both individually and with other burners operating.
Low flame operation verified.
All burner caps, burner rings and burner bases correctly seated in position, level, and do not rock or slide.
Burner grates correctly positioned, level, and do not rock.
INSTALLER FINAL CHECKLIST
US
CA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fisher & Paykel DCS CDU Series and is the answer not in the manual?

Fisher & Paykel DCS CDU Series Specifications

General IconGeneral
BrandFisher & Paykel
ModelDCS CDU Series
CategoryCooktop
LanguageEnglish

Related product manuals