12
7.0 REPLACEMENT & SERVICING OF FLAME FAILURE
(Refer also Section 9 - Problem Solving)
7.1 To Test Flame Failure
7.1.1 Ensure thermocouple is held in the flame even if the hob is removed.
7.1.2 Ignite the burner, hold the knob down for five seconds. Release. Burner should stay alight.
7.1.3 Turn down to low and blow out. After about 10-15s, the flame failure should stop the flow of gas.
(You should hear a click).
7.1.4 If 7.1.2 or 7.1.3 are not met (see Section 9 - Problem Solving).
7.2 To Replace a Thermocouple
7.2.1 Remove the hob (see Section 4).
7.2.2 Unscrew (small hex, 8 AF) from end of gas valve and replace.
7.2.3 Test thermocouple works before replacing hob.