DATE: 20.04.2015
IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm
(/2''). Please read the installation manual for detailed information on
installing the product. www.fisherpaykel.com
CAVITY PREPARATION
900mm ActiveSmart™ Slide-in Refrigerator
Model no:
RS90AU1 (with Stainless Steel Door panels PART NO. RD90U)
RS90A1 (with Stainless Steel Door panels PART NO. RD90)
RS90A1
Cavity Dimensions
mm
a Overall height of cavity
1800
B Overall width of cavity
when adjoining cabinetry can share 4mm door gap
900
when adjoining cabinetry cannot share 4mm door gap
904
c Overall depth of cavity
650
Specifications RS90A1
Electrical
Supply
20 VAC, 50 Hz
Service
10 amp circuit
Specifications
RS90AU1
Electrical
Supply
20 VAC, 50 Hz
Service
10 amp circuit
Plumbing
Supply
1/2" BSP threaded water connection, 6.5mm PEX
tubing
Pressure
Minimum 22 psi (150 kPa)
Maximum 120 psi (827 kPa) @ 20°C
NOTE: Recommended that the electrical & water connection be located in an
adjacent cabinet to either side of the fridge or above the fridge cavity.
Do not locate water or electricity in this area, keep clear of connections.
CAUTION: Central area can only fit water outlet and electrical plug if they are
placed within a recessed cavity.
* In this location the water tap needs to be recessed into the wall, the recess
must allow for an 80mm bend radius for the water tube.
!