Fisher Scientific accumet AB200 User Manual

Fisher Scientific accumet AB200
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Instruction Manual
Fisher Scientific
accumet
®
Basic (AB)
Benchtop Meters
AB150 AB200 AB250
68X613601 Rev 0 Jul
y
201
2

Questions and Answers:

Fisher Scientific accumet AB200 Specifications

General IconGeneral
pH Resolution0.01 pH
pH Accuracy±0.01 pH
mV Resolution1 mV
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
Calibration PointsUp to 5 points
DisplayLCD
pH Range0 to 14 pH
mV Range-2000 to +2000 mV
Temperature Range-5.0 to 105.0°C
InputspH, mV, Temperature
OutputsRS232
Power4 x AA batteries or AC adapter

Summary

Introduction

Keypad and Display Overview

Fixed Key Functions

Describes the purpose and operation of the meter's fixed buttons.

Soft Key Functions

Describes the purpose and operation of the meter's soft keys.

Meter Connections and Ports

System Setup and Configuration

Stability Indicator Settings

Adjusts the frequency and speed of the 'Stable' indicator appearance.

Export Data Settings

Configures data printing and datalogging options.

Communication Setup Options

Sets up RS-232 or USB communication for data transfer.

Date and Time Settings

Configures the instrument's date and time for GLP functions.

Password Protection Setup

Enables or disables password protection for setup and calibration.

Factory Reset Function

Resets meter settings to factory defaults, excluding date/time/data.

Display Contrast Adjustment

Optimizes display visibility by adjusting contrast levels.

Stirrer Speed Settings

Sets the stirring speed for the optional benchtop stirrer.

Sample Identification Setup

Assigns a unique ID to data points for identification.

Language Selection

Selects the preferred display language for the instrument.

Key Press Beep Setting

Enables or disables audible tones for key presses.

pH and mV Setup

pH Buffer Group Selection

Choose from predefined pH buffer groups for calibration.

pH Resolution Settings

Select the desired pH resolution (X.X, X.XX, X.XXX).

Alarm Configuration

Sets visual and audible alarms for high/low value limits.

Standard Due Alarm Setting

Configures the "Cal Due" indicator for calibration reminders.

pH Standardization with Preset Buffers

pH Standardization with Custom Buffers

mV Standardization (Offset Adjustment)

Temperature Unit Setup

Temperature Standardization

Conductivity, TDS, Salinity, & Resistivity Setup

Standardization Method for Conductivity

Selects automatic or manual standardization for conductivity.

Standardization Points Selection

Chooses between single-point or multi-point calibration.

Automatic Conductivity Standardization

Manual Cond/TDS/Salinity/Resistivity Standardization

Ion Measurement Setup

Ion Measurement Units

Selects units for ion concentration (ppm, molar, mg/L).

Ion Measurement Alarm Settings

Configures high/low alarms for ion measurements.

Ion Standardization Due Alarm

Sets reminders for ion calibration due dates.

Ion Calibration Standard Groups

Selects ISE buffer groups for standardization.

Ion Standardization Procedure

Data Viewing, Transfer, and Printing

Standardization Report Details

Troubleshooting Guide

USB Driver and Boot Loader Documentation

Windows XP USB Driver Installation

Step-by-step guide for installing the USB driver on Windows XP.

Windows 7 USB Driver Installation

Meter Firmware Boot Loading Procedure

Instrument Specifications

Replacements and Accessories

Product Warranty Information

Return of Items Policy

Notice of Compliance and WEEE

Declaration of Conformity

Related product manuals