Fisher Scientific Accumet Basic AB30 User Manual

Fisher Scientific Accumet Basic AB30
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Question and Answer IconNeed help?

Do you have a question about the Fisher Scientific Accumet Basic AB30 and is the answer not in the manual?

Fisher Scientific Accumet Basic AB30 Specifications

General IconGeneral
pH Resolution0.01 pH
pH Accuracy±0.01 pH
mV Range±1999 mV
mV Resolution1 mV
mV Accuracy±1 mV
Temperature Range-5.0 to 105.0 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.5 °C
DisplayLCD
Auto Shut-offYes
Calibration PointsUp to 3 points

Summary

Introduction to the Accumet AB30 Meter

Unpacking the Accumet AB30 Meter

Getting Started with the Accumet AB30

Connectors on the Accumet AB30

Explains the layout and function of the rear connector panel on the meter.

Using the Accumet AB30 Meter

Conductivity Probes for the AB30

Describes how to connect and prepare 2-cell and 4-cell conductivity probes.

Display and Keys Overview

Overviews the meter's screen display and the function of its keys.

Understanding the Screen Display

Familiarizes the user with the layout and elements of the digital screen display.

Conductivity Operation of the AB30

Using the Setup Menu

Explains how to access and configure operating parameters for the meter.

Setup from the Measure Screen

Describes navigating and changing parameters within the setup menu from the measure screen.

Program 1: View Calculated Cell Constant

Instructs on how to view the stored cell constant value in the meter's memory.

Program 2: View Standardized Value

Guides the user on how to check the last standardized value recorded by the meter.

Program 3: Select Conductivity Mode

Explains how to choose and set the conductivity measurement mode.

Program 4: Select Resistivity Mode

Details the process for selecting and setting the resistivity measurement mode.

Program 5: Select TDS Mode

Covers how to select and configure the Total Dissolved Solids (TDS) measurement mode.

Program 6: Select Cell Constant 1.00

Shows how to set the nominal cell constant to 1.00 for measurements.

Program 7: Select Cell Constant 10.00

Guides on setting the nominal cell constant to 10.00 for measurements.

Program 8: Select Cell Constant 0.10

Explains how to set the nominal cell constant to 0.10 for measurements.

Program 9: Select Temperature Coefficient 2.0%

Details how to select a 2.0% temperature coefficient for compensation.

Program 10: Select Temperature Coefficient 5.2%

Guides on selecting a 5.2% temperature coefficient for compensation.

Program 11: Select Temperature Coefficient 0.0%

Explains how to select a 0.0% temperature coefficient for compensation.

Program 12: Select Temperature Coefficient 1.5%

Covers selecting a 1.5% temperature coefficient for compensation.

Program 13: Select TDS Factor (0.40-1.00)

Instructs on adjusting the TDS factor within the specified range.

Program 14: Temperature Unit Selection (°C)

Describes how to set the temperature unit to Celsius (°C).

Program 15: Temperature Unit Selection (°F)

Guides on setting the temperature unit to Fahrenheit (°F).

Program 16: Enable STABLE Icon

Explains how to turn on the STABLE icon for reading stability indication.

Program 17: Disable STABLE Icon

Details how to turn off the STABLE icon display.

Program 18: Clear User Standardization

Guides on resetting or clearing the meter's calibration data.

Standardization of the Accumet AB30

Using Setup for Standardization

Explains how to use the setup menu to prepare for standardization.

Resistivity and TDS Standardization

Describes the standardization procedures for resistivity and TDS modes.

Measurement Procedures

Conductivity Measurement

Details the steps for taking conductivity measurements with the meter.

Resistivity Measurement

Explains how to perform resistivity measurements using the device.

TDS Measurement

Covers the procedure for taking Total Dissolved Solids (TDS) measurements.

Temperature Measurement

Describes how the meter handles temperature readings and ATC calibration.

Conductivity Operation Details

Replatinization of Conductivity Probes

Explains the process of replatinizing the conductivity probe to maintain performance.

Conductivity Theory and Principles

The Four-Cell Electrode

Discusses the advantages and operation of the four-cell electrode design.

Conductivity and Temperature Relationship

Explains the relationship between conductivity and temperature, and compensation methods.

Cleaning the Accumet AB30 Meter

Accumet AB30 Meter Specifications

Accumet AB30 Warranty Information

Notice of Compliance for Accumet AB30

Replacement Parts for Accumet AB30

List of Replacement Parts

Provides a list of specific replacement parts for the meter and accessories.