SECTION 1
INFORMATION AND REQUIREMENTS
1.0 APPLIANCE INFORMATION
Model FHEC**MN (MC) FHEC**SP (SC)
FHEC**SN (SC)
FHEC**RN2 (RC)
Gas Type G20 G31
Main injectors (2 off) Size 160 (MC & SC) 190 (RC) Size 86
Pilot Type (MC) Copreci 21100/141 Copreci 21100/263
Pilot Type (SC) Copreci 21100/162 or
Pilot Type (RC) ERTA PG-83-10 ERTA PG-82-310C
Max. Gross Heat Input : 5.0 kW 5.0 kW
Min. Gross Heat Input : 3.5 kW 3.5 kW
Cold Pressure : 20.0+/- 1.0mbar 37.0 +/- 1.0mbar
Ignition : Push Button Piezo (MC models)
1.5V Battery Generator (SC models)
4.5V Battery Generator (RC models)
Electrode Spark Gap 4.5mm Nominal
Weight 26kg (all models)
Fire box Dimensions (with trim fitted)
Width : (with standard trim, no spacer) 498mm
Height : (with standard trim, no spacer) 600mm
Depth : (overall-without fender) 250mm
Depth : Flush-fit (from mounting face to rear) 250mm
Depth : Flush-fit (mounting face to rear 200mm
with 50mm spacer fitted)
Gas Connection 8mm Compression (Supplied with fire)
This appliance is manufactured by :-
BFM Europe Ltd, Trentham Lakes, Stoke-on-Trent, ST4 4TJ
Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2009 + A1 : 2013 and the result is 78.2%. The gross calorific value of
the fuel has been used for this efficiency calculation.
The test data from which it has been calculated has been certified by BSI.
The efficiency value may be used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings.
3