Cycle Type | Downflow |
---|---|
Control Valve | 6700 |
Media Type | Resin |
Backwash Flow Rate | 27 GPM |
Connection Size | 1" NPT |
Power Supply | 120V AC |
Sets water hardness in grains per gallon for system configuration.
Configures water hardness after the mixing valve using metric display.
Sets the total grain capacity of the water softener system.
Sets the scheduled time for the water softener regeneration cycle.
Configures the duration for the Backwash step in the regeneration cycle.
Configures the duration for the Brine Draw/Slow Rinse step.
Configures the duration for the Rapid Rinse step.
Configures the duration for the Brine Tank Refill step.
Configures Step #5, which is typically not used in regeneration.
Exits Option Level #1, returning the system to normal operation.
Procedure to enter the first level of option programming.
Sets the unit of measure for water hardness (grains, French degrees, PPM).
Sets water hardness after the mixing valve using metric formats.
Sets the system's total capacity and unit of measurement.
Programs the duration for up to six regeneration cycle steps.
Sets the scheduled time for regeneration.
Describes how to exit the current option setting level.
Provides important notes for installers regarding settings and operation.
Procedure to enter the second level of option programming.
Displays the current flow rate of treated water through the softener.
Shows days since the last regeneration for diagnostic purposes.
Displays the volume of water used since the last service period.
Shows the calculated reserve capacity for the present day.
Displays the water usage from the previous day.
Sets when the chlorinator indicator turns on during regeneration.
Sets the start time for Timed Auxiliary Output Window #1.
Sets the end time for Timed Auxiliary Output Window #1.
Sets the start time for Timed Auxiliary Output Window #2.
Sets the end time for Timed Auxiliary Output Window #2.
Sets the on-time duration for the chemical pump output.
Sets the volume count for chemical pump output activation.
Sets maximum days before a regeneration cycle is forced.
Sets maximum water usage before a regeneration cycle is called.
Selects the display format (US or various metric options).
Sets the type of valve used with the control unit.
Sets the initiation method for regeneration (e.g., time clock, meter).
Sets the size of the valve flow meter for accurate measurement.
Sets the location of the mixing valve relative to the flow meter.
Sets the type of system the valve is operating within.
Prevents certain displays from being viewed or set for security.
Procedure to enter the second level of option programming.
Displays the current flow rate of treated water through the softener.
Shows days since the last regeneration for diagnostic purposes.
Displays the volume of water used since the last service period.
Shows the calculated reserve capacity for the present day.
Displays the water usage from the previous day.
Sets when the chlorinator indicator turns on during regeneration.
Programs the optional relay output for timed auxiliary functions.
Sets the start and end times for Timed Auxiliary Output Window #1.
Sets the start and end times for Timed Auxiliary Output Window #2.
Configures chemical pump output based on time and flow volume.
Sets maximum days before a regeneration cycle is forced.
Sets maximum water usage before a regeneration cycle is called.
Selects the display format (US or various metric options).
Sets the type of valve used with the control unit.
Sets the initiation method for regeneration (e.g., time clock, meter).
Configures regeneration based on reserve capacity and service flow.
Configures regeneration based on immediate sensor signal.
Configures regeneration based on sensor signal and set time.
Option setting for Regeneration Type #7, not typically used.
Option setting for Regeneration Type #8, not currently used.
Sets the size of the valve flow meter for accurate measurement.
Sets the location of the mixing valve relative to the flow meter.
Sets the type of system the valve is operating within.
Prevents certain displays from being viewed or set for security.