2. Operation (Restoration & Discharge)
MANUAL MODE – DISCHARGE PROCESS
Manual Mode: Discharge is performed with Constant Ampere form.
• This graph shows Discharge
Explanation for the Graph of Discharge
① Start Discharge with Set Ampere until it reaches Set Voltage (Final Voltage for Discharge)
② When Active Voltage reaches Set Voltage , it will complete Discharge Mode regardless of
Set
Time.
③ When it reaches Set Time, it will complete Discharge Mode even though it does not reach
Se
t Voltage. (Regardless of Set Voltage)
**This is same as Pulse 1 in Program Mode.
Don’t discharge under final voltage provided by battery manufacturers for discharging .
Discharge under final voltage specified may cause serious damage to your batteries.
C A U T I O N
Caution