2. Operation (Restoration & Discharge)
MANUAL MODE DISCHARGE PROCESS
Manual Mode: Discharge is performed with Constant Ampere form.
This graph shows Discharge
Explanation for the Graph of Discharge
Start Discharge with Set Ampere until it reaches Set Voltage (Final Voltage for Discharge)
When Active Voltage reaches Set Voltage , it will complete Discharge Mode regardless of
Set
Time.
When it reaches Set Time, it will complete Discharge Mode even though it does not reach
Se
t Voltage. (Regardless of Set Voltage)
**This is same as Pulse 1 in Program Mode.
Don’t discharge under final voltage provided by battery manufacturers for discharging .
Discharge under final voltage specified may cause serious damage to your batteries.
C A U T I O N
Caution