Technical data8
Power system
External power operation
• AC adapter, 90–260 VAC input
• 5 V output to camera
Power management Automatic shut-down
Environmental data
Operating temperature range –10°C to +50°C (14 to 122°F)
Storage temperature range –40°C to +70°C (–40 to 158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C
to +40°C (+77°F to +104°F) / 2 cycles
Relative humidity
95% relative humidity +25°C to +40°C (+77°F to
+104°F) non condensing
EMC
• WEEE 2012/19/EC
• RoHs 2011/65/EC
• C-Tick
• EN 61000-6-3
• EN 61000-6-2
• FCC 47 CFR Part 15 Class B
Magnetic fields EN 61000-4-8
Battery regulations UL 1642
Encapsulation
Camera housing and lens: IP 40 (IEC 60529)
Shock 25 g (IEC 60068-2-27)
Vibration
2 g (IEC 60068-2-6)
Physical data
Weight (incl. Battery) 0.13 kg (0.29 lb.)
Size (L × W × H) 125 × 80 × 24 mm (4.9 × 3.1 × 0.94 in.)
Tripod mounting Yes
Housing material
• PC and ABS, partially covered with TPE
• Aluminum
Color Black and gray
Shipping information
Packaging, type
Cardboard box
List of contents
• Infrared camera
• Lanyard
• Power supply/charger with EU, UK, US, CN
and Australian plugs
• Printed documentation
• Tripod mount
• FLIR C2 educational kit card with download
links for FLIR Tools+, FLIR ResearchIR Stand-
ard (incl. printed license key), and educational
resources.
• USB cable
Packaging, weight 0.53 kg (1.17 lb.)
Packaging, size 175 × 115 × 75 mm (6.9 × 4.5 × 3.0 in.)
EAN-13 4743254002067
#T559918; r. AN/42281/42281; en-US
31