7 Technical specifications
Function Range Resolution Accuracy (of
reading)
AC voltage 400.0 mV 0.1 mV ±(1.5% + 10
digits)
4.000 V 0.001 V ±(1.5% + 5
digits)
40.00 V 0.01 V
400.0 V 0.1 V
1000 V 1 V ±(2.0% + 5
digits)
Note
All AC voltage ranges are specified from 5% of the range to 100% of the
range.
DC voltage 400.0 mV 0.1 mV ±(1.5%+10
digits)
4.000 V 0.001 V ±(1.5% + 2
digits)
40.00 V 0.01 V
400.0 V 0.1 V
1000 V 1 V ±(2.0% + 2
digits)
Resistance
400.0 Ω 0.1 Ω ±(1.0% + 4
digits)
4.000 0.001 ±(1.5% + 2
digits)
40.00 0.01
400.0 0.1
4.000 0.001 ±(2.5% + 3
digits)
40.00 0.01 ±(3.5% + 5
digits)
#T559826; r. AD/ 9130/9130; en-US 26