Operation
12
Figure 12.2 TI Basic NFPA mode.
TI Basic NFPA mode is the default mode of the camera. It is a multipurpose mode for the
initial fire attack with life-saving operations and control of the fire. The camera automati-
cally switches between the high-sensitivity range and the low-sensitivity range, to main-
tain an optimal infrared image while at the same time maintaining a safe and consistent
heat colorization of the fire scene.
Automatic range.
Colorization of heat: +150 to +650°C (+302 to +1202°F).
High-sensitivity range: –20 to +150°C (–4 to +302°F).
Low-sensitivity range: 0 to +650°C (+32 to +1202°F).
Note
To go to TI Basic NFPA mode from any other mode, push and hold the on/off button
for less than 1 second.
In TI Basic NFPA mode, the spotmeter, spotmeter temperature, and temperature bar
are not displayed.
12.5.2.3 Black and white firefighting mode
Figure 12.3 Black and white firefighting mode.
Black and white firefighting mode is a standardized firefighting mode based on Basic
mode. It is a multipurpose mode for the initial fire intervention that includes life-saving op-
erations and control of the fire. It is specifically designed for fire services that do not want
to use the heat colorization feature.
The camera automatically switches between the high-sensitivity range and the low-sen-
sitivity range, to maintain an optimal infrared image.
Automatic range.
High-sensitivity range: –20 to +150°C (–4 to +302°F).
#T559946; r. BG/87484/87484; en-US