Operation
12
12.5.1.1 Figure
1. LCD area.
2. Area activating the automatic range change.
12.5.2 Explanation of the different camera modes
12.5.2.1 Basic mode
Note Basic mode is applicable to FLIR K45 and FLIR K55 cameras.
Figure 12.1 Basic mode.
Basic mode is the default mode of the camera. It is a multipurpose mode for the initial fire
attack with life-saving operations and control of the fire. The camera automatically
switches between the high-sensitivity range and the low-sensitivity range, to maintain an
optimal infrared image while at the same time maintaining a safe and consistent heat col-
orization of the fire scene.
Automatic range.
Colorization of heat: +150 to +650°C (+302 to +1202°F).
High-sensitivity range: –20 to +150°C (–4 to +302°F).
Low-sensitivity range: 0 to +650°C (+32 to +1202°F).
Note To go to Basic mode from any other mode, push and hold the on/off button for
less than 1 second.
12.5.2.2 TI Basic NFPA mode
Note TI Basic NFPA mode is applicable to NFPA 1801-2021 certified FLIR K65
cameras.