1.3 UltraFORCE 350-HD Operation
1.3.1 Power-on (start-up) procedure:
Ensure that the TCU has mechanical freedom of movement and that no
interference from surrounding objects/obstructions is present.
Ensure that the TCU is placed in STOW position before the system is powered
on.
Ensure that a stable DC power supply is available.
NOTE: Do not power-on the TCU during aircraft engine start-up.
Ensure that a monitor is correctly connected and powered up.
Power-on the system using the HCU. (see § 1.4.1)
Perform a Joystick calibration, as described in § 1.4.7.
Null any Azimuth and Elevation drift, as described in § 1.4.12 and 1.4.13.
NOTE: This action should be performed when the system has warmed up in order to achieve
the best result.
The system will start-up and initialize according to the conditions defined below:
NOTE: The thermal imager will need a cool down period of approx. 7 min before an
image is displayed. The TI display is showing INIT during this period (See § 1.5.6)
Avoid to power-off the TCU during the initialization phase.
Condition after initialization
Last CAGE setting (or STOW if STOW
switch is selected)
Push forward for negative elevation
No Electronic Zoom selected
No Electronic Zoom selected