√ One 10” sediment fi lter (part no. 104017) √ Bucket to catch water from fi lter housings.
√ Two 10” carbon fi lters (part no. 101009)
Clean all fi lter housings (bowls) with a mild soap solution and rinse
with water. Check O-rings and lubricate with water soluble lubricant.
KY Jelly® , Canola oil and other water based lubricants can be used,
petroleum based lubricants (such as Vaseline
®) must not be used.
For more leverage, leave RO module attached to wall of cabinet. If
you are unable to access the module you may remove it to change
fi lters. Starting with the closest housing, remove and empty water, then
discard fi lters. Continue on to the 2
nd
and/or 3
rd
Bowls.
The sediment fi lter has a cloth like appearance. It should be in the 1
st
housing on the side with tubing connections.
6 Month System Maintenance
Turn off incoming water supply to the RO by turning the needle valve
on the adapta valve clockwise. (The green tube is connected to the
adapta valve.)
Let system sit for 10 – 15 minutes after tank is empty to depressurize
before attempting to remove fi lter housings.
Open RO Faucet to allow water to drain from the tank until completely
empty. Water can be saved in a container for drinking or to rinse
system parts.
Check O-rings to make sure they are still in place.
Insert the Carbon Block fi lter (fi lter has a gasket on each end) into
the middle housing.
Repeat this step for 3
rd
housing .
Open RO faucet and leave open until water begins to trickle out.
Close RO faucet to allow tank to fi ll with water.
Check O-rings to make sure they are still in place. Check O-rings to make sure they are still in place.
Turn water on to the unit by turning the needle valve on the adapta
valve counter clock wise.
If also doing the annual maintenance at this time continue to Step 2