FLUKE 112 / 115 TRUE RMS MULTIMETER Quick Start Guide
The Fluke 112 / 115 is a multimeter (volt-ohm-milliameter, or VOM, in some references) designed for
basic circuit measurements. Instrument settings are accessed via the main dial on the front. The
positions (which vary somewhat between the models) are (bold represents the ones we’ll use the most):
OFF: instrument off
Return the dial here when you are finished using the meter.
V~~: measures AC voltage (voltmeter)
V==: measures DC voltage (voltmeter)
mV: measures small DC voltages, with higher accuracy
: measures resistance (ohmmeter)
Note: the ohmmeter setting should never be used on an
energized circuit! It is only used to measure the resistance
of de-energized resistors. At best, measuring an
energized component will give incorrect values. At worst it
will blow a fuse inside the meter.
●))): continuity tester (audible ohmmeter).
This is useful for detecting short/open circuits; the system
beeps when low resistance is encountered, so you can check
many connections without looking at the display.
: Diode tester. (We will discuss this later.)
A~~: measures AC current (ammeter)
A==: measures DC current (ammeter)
)| : measures capacitors
This works similarly to the ohmmeter setting, and should only be used on a de-energized
component. Just as the ohmmeter measures resistance values, this gives capacitance values.
Hz: frequency meterdetermines the frequency of an AC signal.
Other buttons:
HOLD: holds the current displayed value on screen. (Useful for copying values into your notes!)
RANGE: selects between auto-range and manual range selection
“Orange” button: used to select “orange” options on dial.
MIN MAX: display the minimum, maximum, or average values of the present measurement.
“sun” symbol: turns on display backlight
To use the meter, you connect two cords (one red and one black) to the bottom terminals as follows:
Black cord: always goes to the COM connector (center)

Other manuals for Fluke 112

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 112 and is the answer not in the manual?

Fluke 112 Specifications

General IconGeneral
CategoryMultimeter
ContinuityYes
Diode TestYes
DisplayDigital
DC Voltage Ranges400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600 V
Resistance Ranges400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ
Safety CategoryCAT III 600 V
AC Voltage Accuracy±(1.0% + 3)
Battery Type9 V
DC Voltage Accuracy±(0.5% + 2 counts)
AC Voltage Ranges4.000 V, 40.00 V, 400.0 V, 600 V