EasyManua.ls Logo

Fluke 115C - Input Characteristics and Rejection Ratios

Fluke 115C
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
True-rms Multimeters
General Specifications
23
Table 2. Input Characteristics
Function
Input Impedance
(Nominal)
Common Mode Rejection Ratio
(1 kΩ Unbalanced)
Normal Mode
Rejection
Volts AC >5 MΩ <100 pF >60 dB at dc, 50 or 60 Hz
Volts DC
>10 MΩ <100 pF >100 dB at dc, 50 or 60 Hz
>60 dB at 50 or 60
Hz
Auto-V LoZ ~3 kΩ <500 pF >60 dB at dc, 50 or 60 Hz
Open Circuit Test Voltage Full Scale Voltage
Short Circuit
Current
To 6.0 MΩ 40 MΩ Ohms <2.7 V dc
<0.7 V dc <0.9 V dc
<350 μA
Diode Test <2.7 V dc 2.000 V dc <1.2 mA

Related product manuals