Accuracy specifications
2 Fluke Corporation 117 Electrician’s Multimeter with Non-Contact Voltage
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2006 Fluke Corporation. All rights reserved.
Printed in U.S.A. 8/2006 2634028 D-EN-N Rev A
Fluke. Keeping your world
up and running.
Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
DC millivolts 600.0 mV 0.1 mV 2.0 % + 3
DC volts 6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts
1
true-rms
600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts
1
true-rms 6.000 V 0.001 V
1.0 % + 3 (45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
60.00 V 0.01 V
600.0 V 0.1 V
Continuity 600 Ω 1 Ω Beeper on < 20 Ω off > 250 Ω; detects
opens or shorts of 500 µs or longer.
Ohms 600.0 Ω 0.1Ω 0.9 % + 2
6.000 k
Ω 0.001 kΩ
0.9 % + 1
60.00 k
Ω 0.01 kΩ
600.0 k
Ω 0.1 kΩ
6.000 M
Ω 0.001 MΩ
40.00 M
Ω 0.01 MΩ 1.5 % + 2
Diode test 2.000 V 0.001 V 0.9 % + 2
Capacitance 1000 nF 1 nF
1.9 % + 210.00 µF 0.01 µF
100.0 µF 0.1 µF
9999 µF 1 µF
100 µF to 1000 µF 1.9 % + 2
> 1000 µF 5 % + 20
Lo-Z capacitance 1 nF to 500 µF 10 % + 2 typical
AC amps true-rms
(45 Hz to 500 Hz)
6.000 A 0.001 A
1.5 % + 3
10.00 A 0.01 A
20 A continuous overload for 30 seconds max.
DC amps 6.000 A 0.001 A
1.0 % + 3
10.00 A 0.01 A
20 A continuous overload for 30 seconds max.
Hz (V or A input)
2
99.99 Hz 0.01 Hz
0.1 % + 2
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
50.00 kHz 0.01 kHz
Notes:
1
All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified,
it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected
from a circuit or are shorted together. For volts, crest factor of
3 at 4000 counts, decreasing linearly to 1.5 at full
scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2
Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
Ordering
information
Fluke-117 Electrician’s
Multimeter with
Non-Contact Voltage
Included
TL75 Test leads, holster, User’s
manual and 9V battery (installed).

Other manuals for Fluke 117

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 117 and is the answer not in the manual?

Fluke 117 Specifications

General IconGeneral
Diode testYes
Product typeDigital multimeter
Product colorBlack, Yellow
Measuring categoryCAT III 600V
Placement supportedHandheld multimeter
Battery type9V
Power sourceBattery
Battery technologyAlkaline
Number of batteries supported1
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)-10 - 50 °C
Weight and Dimensions IconWeight and Dimensions
Depth46 mm
Width84 mm
Height167 mm
Weight550 g

Related product manuals