EasyManua.ls Logo

Fluke 179 - Electrical Specs: Capacitance and Current; Diode, Capacitance, and Amps Specs; Frequency Measurement Specifications

Fluke 179
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
True-rms Multimeters
Electrical Specifications
21
Function Range
[1]
Resolution
Accuracy ±( [ % of Reading ] + [ Counts ] )
175 177 179
Diode test 2.400 V 0.001 V 1 % + 2
Capacitance
1000 nF
10.00 μF
100.0 μF
9999 μF
[4]
1 nF
0.01 μF
0.1 μF
1 μF
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
AC Amps
[5]
(True-rms)
(45 Hz to 1 kHz)
60.00 mA
400.0 mA
[6]
6.000 A
10.00 A
[7]
0.01 mA
0.1 mA
0.001 A
0.01 A
1.5 % + 3 1.5 % + 3 1.5 % + 3
DC Amps
[5]
60.00 mA
400.0 mA
[6]
6.000 A
10.00 A
[7]
0.01 mA
0.1 mA
0.001 A
0.01 A
1.0 % + 3 1.0 % + 3 1.0 % + 3
Hz
(AC- or DC- coupled,
V or A
[8] [9]
input )
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 % + 1 0.1 % + 1 0.1 % + 1

Other manuals for Fluke 179