Fluke 179 - Electrical Performance Characteristics; Overload Protection and Input Impedance; Mode Rejection Ratios; Short Circuit Current Limits

Fluke 179
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
True-rms Multimeters
Electrical Specifications
23
Function Overload Protection
[1]
Input Impedance
(Nominal)
Common Mode Rejection Ratio
(1 kΩ Unbalanced)
Normal Mode Rejection
Volts ac 1000 V rms >10 MΩ < 100 pF >60 dB @ dc, 50 Hz or 60 Hz
Volts dc 1000 V rms >10 MΩ < 100 pF >120 dB @ dc, 50 Hz or 60 Hz >60 dB @ 50 Hz or 60 Hz
mV/ 1000 V rms
[2]
>10 MΩ < 100 pF >120 dB @ dc, 50 Hz or 60 Hz >60 dB @ 50 Hz or 60 Hz
Open Circuit Test
Voltage
Full Scale Voltage To:
Short Circuit Current
600 kΩ 50 MΩ
Ohms/Capacitance 1000 V rms
[2]
<8.0 V dc <660 mV dc <4.6 V dc <1.1 mA
Continuity/Diode test 1000 V rms
[2]
<8.0 V dc 2.4 V dc <1.1 mA
[1] 10
7
V-Hz maximum.
[2] For circuits <0.3 A short circuit. 660 V for high energy circuits.
Function Overload Protection Overload
mA Fused, 44/100 A, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
A Fused, 11 A, 1000 V FAST Fuse 20 A overload for 30 seconds maximum, 10 minutes rest minimum