Do you have a question about the Fluke 187 and is the answer not in the manual?
Frequency Range | 0.5 Hz to 1 MHz |
---|---|
Safety Rating | CAT III 1000V, CAT IV 600V |
AC Voltage Range | 0.1 mV to 1000 V |
AC Current Range | 0.1 µA to 10 A |
DC Voltage Accuracy | ±(0.025% + 2) |
AC Voltage Accuracy | 0.4% + 40 digits (True RMS) |
Resistance Accuracy | ±(0.05% + 2) |
Temperature Range | -200°C to 1350°C |
Operating Temperature | -20 °C to +55 °C |
Battery Type | 9V (NEDA 1604) |
Essential safety guidelines and warnings for using the multimeter.
Details on battery usage and techniques for conserving battery power.
Description of the rotary switch positions and their functions.
Understanding voltage, its types (AC/DC), and available ranges.
Procedure for measuring AC voltage, including true RMS and waveform types.
Procedure for measuring DC voltage.
Procedure for measuring electrical resistance (ohms) and safety precautions.
How to test for a complete circuit path using the continuity beeper.
How to measure electrical capacitance and its related precautions.
Procedure for testing diodes and other semiconductor junctions.
How to measure temperature using a thermocouple probe.
Procedure for measuring AC or DC current, including safety warnings.
Procedure for measuring AC current and available ranges.
Procedure for measuring DC current and viewing its components.
How to measure signal frequency and its applicable functions.
Procedure to test the multimeter's fuses before measuring current.
Step-by-step guide on how to replace the multimeter's AA batteries.
Instructions on how to safely examine or replace the multimeter's fuses.
Details on safety standards, compliances, and voltage ratings.
Dimensions, weight, operating temperature, battery life, and other physical attributes.
A concise summary of the key features and their descriptions.
Table of basic specifications for different functions like voltage, current, resistance.
Comprehensive accuracy specifications for various functions and ranges.