EasyManua.ls Logo

Fluke 27 - General Maintenance

Fluke 27
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operator Maintenance
19
Table 4. Replacement Fuses
Item Description PN Qty
F1
W
Fuse, F44/100A,
1000 VAC/DC
943121 1
F2
W
Fuse, F11A, 1000
VAC/DC
803293 1
W To ensure safety, use exact replacement only
General Maintenance
Clean the case with a damp cloth and detergent; do not
use abrasives or solvents.
The Fluke 27 is sealed to protect the instrument. To
maintain proper sealing, open only the battery/fuse
compartment.
Have the meter calibrated and the seals (part number
738112) replaced by a qualified technician once a year to
ensure specified performance. Contact the nearest Fluke
Service Center or refer to the Fluke 27 Service Manual
(part number 690206) for calibration or repair. Refer to
Table 5 for replaceable parts.
Table 5. Replaceable Parts
Item Description PN Qty
BT1 Battery, 9V 696534 1
H6 Screw, PH 6-32 x 3/8 682070 4
MP11 Foot, Case 654335 1
MP12 Bail, Tilt (Bracket) 744474 1
MP14 Cover, Battery 670585 1
MP15 O-Ring, Battery 697185 1
MP16 Spacer, Battery 665023 1
MP61 Fuse Cover 665031
TL75* Test Lead Set 1
AC70* Allicator Clip Set 1
TM1 Users Manual 690203 1
TM2 Service Manual 690206 1
*Accessory Number

Other manuals for Fluke 27