Do you have a question about the Fluke 28 II Ex and is the answer not in the manual?
Diode test | Yes |
---|---|
Product type | Digital multimeter |
Product color | Black, Red |
Frequency range | 0.0005 - 199.99 kHz |
DC current range | 0.0000001 - 10 A |
DC voltage range | 0.0001 - 1000 V |
Resistance range | 0.1 - 50000000 Ω |
Measuring category | CAT IV 600V |
Placement supported | Handheld multimeter |
Basic accuracy (frequency) | 0.005% |
Basic accuracy (DC current) | 0.2% |
Basic accuracy (DC voltage) | 0.05% |
Temperature measurement range | -200 - 1090 °C |
Battery type | AAA |
Power source | Battery |
Battery technology | Alkaline |
Number of batteries supported | 3 |
Operating altitude | 0 - 2000 m |
Maximum storage altitude | 10000 m |
Operating relative humidity (H-H) | 0 - 80 % |
Depth | 198.1 mm |
---|---|
Width | 100 mm |
Height | 6.35 mm |
Weight | 698.5 g |
Provides contact information for Fluke technical support, calibration, and repair services worldwide.
Safety regulations for operating the product in hazardous areas, highlighting potential consequences of non-compliance.
Guidelines to prevent personal injury in mining hazardous areas, covering mechanical burdens and contact with fluids.
Precautions for preventing electrical shock, fire, or injury in all operation areas, including PPE and codes.
Automatically turns off the product after a period of inactivity to conserve battery power.
Warns of incorrect lead connections to current terminals to prevent measurement errors and damage.
Instructions for measuring AC and DC voltage, including range selection and waveform accuracy.
Explanation of how true-rms meters behave with open or shorted inputs in AC functions.
Describes the AC low-pass filter for improved measurement of noisy signals and composite waveforms.
Procedure for measuring temperature using the included type-K thermocouple.
Diagram illustrating the components of duty cycle measurements, including trigger points and percentage.
Instructions for cleaning external surfaces and terminals to ensure accurate measurements.
Procedure to test fuses and identify potential issues with probe insertion or fuse integrity.
Presents AC voltage measurement ranges, resolution, and accuracy specifications across various frequencies.
Details specifications for DC voltage, conductance, and resistance measurements.
Provides temperature measurement ranges, resolution, and accuracy, including notes on thermocouple error.
Details AC current measurement ranges, resolution, burden voltage, and accuracy.
Details DC current measurement ranges, resolution, burden voltage, and accuracy.
Provides capacitance measurement ranges, resolution, and accuracy, including notes on using rel mode.
Details frequency measurement specifications.
Specifies accuracy for diode measurements.
Details minimum sensitivity and trigger levels for frequency counter operations.
Details duty cycle measurement specifications for Vdc and mVdc.
Provides input characteristics like overload protection, impedance, and rejection ratios.
Details specifications for MIN MAX recording response times and accuracy.