28 II Ex 
Users Manual 
38 
Touch top half
of input contacts
Good 11 A fuse: 0.0 Ω to 
 0.5 Ω
Replace fuse: OL
Good 0.44 A fuse: 0.995 kΩ  to
 1.005 kΩ
Replace fuse: OL
 
grt08.eps 
Figure 10. Current Fuse Test 
How to Replace the Batteries 
Replace the batteries with three AAA 
batteries (NEDA 24A IEC LR03). 
XWWarning 
To prevent electrical shock or personal 
injury: 
•  Replace the batteries when the low 
battery indicator () shows to prevent 
incorrect measurements. If the display 
shows “” the Product will not 
function until the batteries are replaced. 
•  Use only three AAA 1.5-volt batteries, 
correctly installed to power the Product. 
See item 5.1 in the Safety Information for 
a list of approved batteries. All batteries 
are to be replaced at the same time with 
same part number batteries outside the 
Ex-hazardous area.