True RMS | Yes |
---|---|
Temperature | -40 °C to 400 °C |
Continuity | Yes |
Diode Test | Yes |
Safety Rating | CAT III 600V |
Voltage DC | 600V |
Voltage AC | 600V |
Current DC | 10A |
Current AC | 10A |
Resistance | 40MΩ |
Battery Life | 400 hours |
Warranty | 3 years |
Explains warning, ground, and attention symbols found on the equipment.
Advises using only the specified fuse type for fire hazard prevention.
Details Class I grounding requirements for electrical shock prevention.
Warns against cover removal due to personal injury risk and lack of user-serviceable parts.
Introduces a short exercise to teach front panel operations to new users.
Recommends a 30-minute warm-up period for the calibrator to meet specifications.
Describes how to enter error mode using the rotary knob and arrow keys.
Explains how to check meter error at 100V dc and 1V using error mode.
Describes the output display, showing amplitude, frequency, and annunciators.
Explains the control display for data entries, softkey labels, and messages.
Toggles between operate and standby modes, and conditions for auto-standby.
Aborts current state and returns to power-up default in local operation.
Explains the EX SNS key's function for opening/closing sense connections.
Outlines conditions for using external sensing in voltage and resistance functions.
Explains the EX GRD key's function for voltage guard connections.
Describes enabling/disabling the Wideband AC option and its connector.
Enables/disables amplifier output and sets standby mode if output location changes.
Aborts current operation and recalls the previous menu.
Describes how functions are accessed through unlabeled softkeys and menus.
Details output adjustment using rotary knob and arrow keys.
Identifies linearity endpoints and multiplies values by a scale factor.
Calls menu to set operational limits for user and equipment protection.
Changes output to one-tenth or ten times the reference value within limits.
Computes and displays uncertainty for the current output setting.
Identifies zero-scale endpoint and adds offset to subsequent keyed-in outputs.
Clears partially completed keypad entries or error messages.
Establishes the present output as a new reference during error mode operation.
Shows the equivalent dBm output for AC voltage or wideband functions.
Loads keyed-in output values and recalls reference in error mode.
Allows selection of output functions like Voltage, Current, Resistance, Frequency.
Enables selection of output value multipliers: micro, milli, kilo, mega.
Used for entering digits for output amplitude, frequency, time, and date.
Toggles output polarity or converts AC voltage/current to DC.
Type 'N' connector for output from the Wideband AC option.
Describes GND binding post for connecting to earth ground as a system reference.
External connection for internal voltage guard, used for UUTs with floating or grounded inputs.
Explains use of SENSE binding posts for sensing at the UUT.
Defines LO, HI, and AUX CURRENT OUTPUT binding posts for signal output.
Describes analog/digital interface connectors for various Fluke amplifiers.
Provides access to a variable-phase 2.5V rms sine wave signal.
Input for external signal to phase lock the calibrator output.
Standard interfaces for remote control operations.
External connection point for the internal current guard.
Internally grounded binding post for connecting instruments to earth ground.
Enables/disables writing to nonvolatile memory for calibration data.
Locates the fuse holder and line voltage selection switches.
Diagrams for connecting UUT for DC and AC voltage up to 10 kHz.
Diagrams for connecting UUT for AC voltage above 10 kHz.
Diagrams for connecting UUT for AC current up to 2A.
Diagrams for connecting UUT for resistance measurements (2-wire/4-wire).
Diagrams and notes for connecting UUT to Wideband AC Voltage Output.
Diagram for connecting UUT to 5725A Amplified Current Output.