368/368 FC/369/369 FC
Users Manual
16
Magnetic Field
IEC 61557-13 E11 (15 Hz to 400 Hz)
10 A/m Class 3
30 A/m Class 2
1.58 %
4.75 %
2.07 %
6.21 %
3.54 %
10.61 %
3.31 %
9.96 %
Load Current
IEC 61557-13 E12
60 A rms max (50 Hz and 60 Hz)
3.60 % 5.17 % 7.67 % 10.83 %
Touch Current
IEC 61557-13 E13 CAT III 600 V/ 60 Hz
0.94 % 0.06 % 1.61 % 0.14 %
Frequency
IEC 61557-13 E14 40 Hz to 1 kHz
0.15 % 0.15 % 0.30 % 0.32 %
Repeatability IEC 61557-13 E15 0.08 % 0.06 % 0.15 % 0.12 %
Uncertainty
IEC 61557-13 B
10A/m Class 3
30A/m Class 2
4.74 %
7.02 %
6.47 %
9.36 %
10.06 %
15.34 %
13.16 %
17.05%
[1] Confidence level: 95 %.
Parameter Specification
Typical
Max
[1]
368/368 FC 369/369 FC 368/368 FC 369/369 FC