AC Leakage Current Clamp
Specifications
15
Wireless Radio
Radio Frequency Certification ..............FCC ID:T68-FBLE IC:6627A-FBLE
Frequency Range.................................2405 MHz to 2480 MHz
Output Power .......................................<100 mW
Radio Frequency Data .........................Go to www.fluke.com
and search for “Radio Frequency Data for
Class A” (PN 4333628)
Operational Error for Current
Accuracy is specified for 1 year after calibration. Accuracy is given as ±(% reading).
Accuracy guaranteed for 50 Hz and 60 Hz.
Parameter Specification
Typical
Max
[1]
368/368 FC 369/369 FC 368/368 FC 369/369 FC
Intrinsic Uncertainty IEC 61557-13 A Reference conditions 0.08 % 0.06 % 0.15 % 0.13 %
Conductor Position IEC 61557-13 E1 ±30 ° 0.08 % 0.06 % 0.15 % 0.12 %
Battery Voltage IEC 61557-13 E2 2.0 V to 3.3 V 0.08 % 0.05 % 0.15 % 0.12 %
Temperature IEC 61557-13 E3 -10 °Cto 50 °C 0.14 % 0.14 % 0.29 % 0.29 %
Distortion IEC 61557-13 E9 0.06 % 0.07 % 0.15 % 0.12 %