Clamp Meter
Specifications
7
DC Voltage
Range
374 and 375 ........................................ 600.0 V
376 ...................................................... 1000 V
Resolution
374 and 375 ........................................ 0.1 V
376 ...................................................... 0.1 V (≤ 600.0 V)
1 V (≤ 1000 V)
Accuracy .................................................1 % ± 5 digits
mV dc
Range
375 and 376.......................................500.0 mV
Resolution...............................................0.1 mV
Accuracy .................................................1 % ± 5 digits
Frequency via Jaw
Range
375 and 376.......................................5.0 - 500.0 Hz
Resolution...............................................0.1 Hz
Accuracy .................................................0.5 % ± 5 digits
Trigger Level...........................................5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range
375 and 376 ...................................... 5.0 – 500.0 Hz
Resolution.............................................. 0.1 Hz
Accuracy ................................................ 0.5 % ± 5 digits
Trigger Level.......................................... 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A
Resistance
Range
374.....................................................6000 Ω
375 and 376.......................................60 kΩ
Resolution
374.....................................................0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
375 and 376.......................................0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy .................................................1 % ± 5 digits
Capacitance
Range .................................................... 1000 μF
Resolution.............................................. 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy .................................................1 % ± 4 digits