16
572
Graphic Display and DIP Settings
D
3
Backlight: Backlight ON or OFF.
Set Default:
Activates the factory defaults.
Setup: Setup HiAlarm and Emissivity adjustment
activated.
Laserflash: The laser flashes when the alarm values
are surpassed.
Laser: activated (ON), not activated (OFF).
The graphic display (3)
shows the temperature as
a
moving bar graph. The
last ten measurements
are shown.
The minimum and
maximum temperature
scale of the graph is set
automatically by the unit
(Auto Range Feature).
Recall previous display
by pushing ENTER (D).
Change the settings in the
unit by using the DIP
switches located in the
battery compartment (see
BATTERIES section).
Lock:
T
rigger locked (ON)
or unlocked (OFF).
°
C/
°
F:
changes between
°C and °F.
Buzzer:Audible alarm ON
or OFF.
SETTINGS
SETTINGS

Other manuals for Fluke 572

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 572 and is the answer not in the manual?

Fluke 572 Specifications

Temperature IconTemperature
temperature range-30 to 900°C (-25 to 1600°F)
ambient operating range0 to 50°C (32 to 122°F)
storage temperature-20 to 50°C (-4 to 122°F)
Display IconDisplay
display resolution0.1°C (0.2°F)
accuracy at 25°C± 0.75% of reading or ± 1K (± 1.5°F)
repeatability±0.5% of reading or ±1°C (±2°F)
Power IconPower
power2 x 1.5 V Alkaline Type AA
battery life13 hrs. (50% laser and 50% backlight used)
response time (95%)250 mSec
Dimensions IconDimensions
dimensions200 x 170 x 50 mm (7.9 x 6.7 x 2 inches)
tripod mount1/4”-20 UNC
optical resolution (standard focus)60 : 1 (19mm spot size at 1.15M)