Safety Information
A Warning identifies conditions and procedures that are dangerous to the user. A Caution
identifies conditions and procedures that can cause damage to the Product or the equipment
under test.
Table 1 tells you about symbols used on the Product and in this manual.
Warning
To prevent possible electrical shock, fire, or personal injury:
Read all safety Information before you use the Product.
Do not use the Product if it operates incorrectly.
Use the Product only as specified, or the protection supplied by the
Product can be compromised.
Examine the case before you use the Product. Look for cracks or
missing plastic. Carefully look at the insulation around the terminals.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 59 MAX and is the answer not in the manual?

Fluke 59 MAX Specifications

General IconGeneral
Temperature Range-30 °C to 500 °C (-22 °F to 932 °F)
Accuracy±2 °C or ±2% of reading, whichever is greater
Distance to Spot Ratio8:1
Response Time< 500 ms (95% of reading)
Operating Temperature0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature-20 °C to 60 °C (-4 °F to 140 °F)
Display TypeLCD
IP RatingIP40
Emissivity0.95
Power1 AA battery
Battery Life12 hours
Dimensions156 x 80 x 50 mm
Spectral Response8 to 14 microns
Display Resolution0.1 °C / 0.1 °F