EasyManuals Logo

Fluke 8020A User Manual

Fluke 8020A
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
Table
1-2.
8020A
Speclflcatlons (Concluded)
---
-
Open
-
Circuit Voltage
...........................
2mS <3.5V
.........................
200nS
<I
.5V
.....................
DiodeTest
..Both ranges will forward bias a typical silicon PN junction.
.............
Overload Protection
.300V dc/rms on all ranges.
DC CURRENT
.........................
Ranges
.f
2 mA,
f
20 mA,
f
200 mA,
f
2000 mA
.......................
Accuracy
.f
(0.75% of reading +1 digit), all ranges
Burden Voltage
2
mA to 200 mA Ranges
........
.0.25V dc max at full scale
2000
mA Range
...............
.0.7V dc max at full scale
..........
Overcurrent Protection
.2 amps max on all ranges. Fuse protected when measuring
current in circuits with open
-
circuit voltage of 250V or less.
AC CURRENT SPECIFICATIONS
.........................
Ranges
.2 mA, 20 mA, 200 mA, 2000 mA
Accuracy
.........
2 mA (45 Hz to 450 Hz)
.f
(2% of reading +2 digits)
........
20 mA, 200 mA, 2000 mA
f
(1.5% of reading +2 digits)
(45 Hz to 1 kHz)
I
Burden Voltage
2
mA to 200 mA Ranges
........
.0.25V rms max at full scale
...............
2000 mA Range
.0.7V rms max at full scale
..........
Overcurrent Protection
.2 amps max on all ranges. Fuse protected when measuring
current in circuits with open
-
circuit voltage of 250V or less.
ENVIRONMENTAL
TEMPERATURE COEFFICIENT
....
.Less than 0.1 times the applicable accuracy specification,per "C
(0" to 18°C and 28" to 50°C)
OPERATING TEMPERATURE
.....
.O
O
to 50°C
STORAGE TEMPERATURE
.........
-
35
"
to 60°C
HUMIDITY
........................
.O
to 90% at 0°C to 35"C, 0 to 80% at 0" C to35" C on 2Mn, 20Mn and
200nS ranges. 0 to 70% at 35°C to 50°C
GENERAL
MAXIMUM COMMON MODE
VOLTAGE
.......................
500V dc/rms ac
..........................
POWER
.9V alkaline or carbon
-
zinc battery (NEDA 1604), or accessory
battery eliminator Fluke Model A
-
81.
..............
Battery Life, Typical
Alkaline 200 hours, carbon
-
zinc 100 to 150 hours
Battery Indicator
................
Display reads BT when battery voltage drops below 7.2 volts,
typically. Approximately
20% of battery life remains.
Battery Eliminator
...............
.Fluke Model A
-
81. Available as an accessory. Specify local line
voltage.
WEIGHT
..........................
.369 gramdl3 ounces (with battery)
SIZE
.............................
.4.5 x
8.6
x 18.0 cm (H x W x
L)
1.8 x 3.4 x 7.1 inches (H x
W
x
L)