Fluke 8024B User Manual

Fluke 8024B
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Question and Answer IconNeed help?

Do you have a question about the Fluke 8024B and is the answer not in the manual?

Fluke 8024B Specifications

General IconGeneral
BrandFluke
Model8024B
CategoryMultimeter
LanguageEnglish

Summary

Section 1 Introduction & Specifications

1.3. Specifications

Detailed technical specifications for the 8024B multimeter.

Section 2 Operating Instructions

2.3. Preparing for Operation

Covers unpacking, battery/fuse installation, and physical features.

2.21. The Display

Explanation of the 3 1/2 digit LCD display, including status indicators.

2.28. AC/DC Volts (V) Operation

Procedure for performing AC and DC voltage measurements.

2.30. AC/DC Current (mA) Operation

Procedure for performing AC and DC current measurements.

2.32. Resistance (Ω) Operation

Procedure for performing resistance measurements.

2.34. Continuity Testing

Using the 2kΩ range for fast continuity tests with audible alarm.

2.36. Diode Testing

Procedure for testing diodes using specific resistance ranges.

2.38. Conductance (S) Operation

Procedure for measuring conductance using Siemens units.

2.40. Temperature (°C) Operation

Procedure for temperature measurement using thermocouple accessories.

2.47. Initial Check-Out Procedure

Simple procedure to verify overall instrument operation after setup.

Section 3 Theory of Operation

Section 4 Maintenance

4.9. Backup Fuse (F2) and Calibration Adjustments

Procedure to access F2 and calibration adjustments.

4.19. Battery/Backup Fuse Replacement

Procedure for replacing the backup fuse (F2).

4.21. Performance Test

Recommended tests to verify instrument specifications.

4.25. Display Test

Procedure to verify proper operation of all LCD indications.

4.27. Voltage Test

Procedure to verify AC and DC voltage measurement functions.

4.29. Current Test

Procedure to verify AC and DC current measurement functions.

4.31. Resistance/Conductance Test

Procedure to verify resistance and conductance measurement functions.

4.33. Peak Hold Test

Procedure to verify proper operation of the peak hold function.

4.35. Continuity Test

Procedure to verify proper operation of the continuity function.

4.37. Level Detector Test

Procedure to verify proper operation of the level detector function.

4.41. Temperature Test

Procedure to verify proper operation of the °C temperature function.

4.43. Calibration Adjustments

Procedure for performing calibration adjustments to maintain specifications.

4.46. Troubleshooting

Guide to diagnosing and resolving instrument malfunctions.

Section 5 List of Replaceable Parts

5.4. How to Obtain Parts

Instructions on how to order replacement components.