Fluke 863 Specifications

General IconGeneral
TypeDigital Multimeter
DisplayLCD
DC Voltage Range0.1 mV to 1000 V
Diode TestYes
Continuity TestYes
Display HoldYes
Min/Max RecordingYes
Auto RangingYes
Safety RatingCAT III 1000 V, CAT IV 600 V
DC Current Range0.1μA to 10A
AC Current Range0.1μA to 10A
Temperature Range-200 °C to +1350 °C (-328 °F to +2462 °F)
Battery Type9V
Battery Life400 hours
Dimensions89 x 49 mm
Measurement FunctionsVoltage, Current, Resistance, Capacitance, Frequency, Temperature, Diode, Continuity

Summary

Limited Warranty and Liability

Chapter 1: Introduction and Specifications

Manual Overview and Product Information

Covers manual introduction, product description, and power requirements.

Options, Service, and Manual Conventions

Details accessories, service info, and manual conventions.

General and Measurement Specifications

Lists general specs and detailed electrical measurement accuracies.

Frequency, Logic, and Advanced Measurement Specs

Covers frequency, logic, component test, and trigger specifications.

Chapter 2: Theory of Operation

Chapter Introduction, Start-Up, and Function Selection

Overviews chapter structure and basic operational sequences.

Power Supply System Operation

Details power sources, outputs, signals, and functional blocks.

Input Signal Conditioning and Waveform Processing

Explains signal conditioning and processing for measurements.

Triggering, Component Test, and Digital Systems

Details triggering, component test, and digital circuitry.

Chapter 3: Maintenance Procedures

Maintenance Introduction, Safety, and Handling

Overview of maintenance, warranty, and static-safe handling.

Cleaning, Disassembly, and Reassembly

Step-by-step instructions for maintenance tasks.

Fuse Replacement Procedures

Guides for replacing internal fuses.

Chapter 4: Performance Testing and Calibration

Introduction, Test Equipment, and Setup

Overviews chapter, lists equipment, and describes setup.

DC Voltage and Diode Performance Tests

Procedures for testing DC Volts, mV DC, and Diode Test.

AC Voltage, Ohms, and Capacitance Tests

Procedures for testing AC Volts, Ohms, Conductance, Capacitance.

Frequency, Current, and Logic Performance Tests

Procedures for testing Frequency, Duty Cycle, Amps, Logic.

Peak Hold, Component Test, and Trigger Tests

Procedures for Peak Hold, Component Test, Glitch Capture, External Trigger.

Calibration Setup and DC Calibration Procedures

Steps for calibration setup and DC calibration.

AC and Resistance Calibration Procedures

Procedures for AC Volts, mAµA, Amps, Ohms/nS calibration.

Internal Constants and LCD Voltage Calibration

Procedures for calibrating internal constants and LCD voltage.

Chapter 5: List of Replaceable Parts

Replaceable Parts Overview and Ordering

Covers parts listing, how to obtain, and manual status.

Service Centers and Detailed Part Listings

Information on service centers and comprehensive part listings.

Chapter 6: Schematic Diagrams

A1 Main PCA Schematic Diagram

Details the main PCA schematic diagram.