Digital Multimeter
Basic Maintenance
7
h
Static Awareness
h
X
Semiconductors and integrated circuits can be damaged by electrostatic
discharge during handling. This notice explains how to minimize damage to
these components.
1. Understand the problem.
2. Learn the guidelines for proper handling.
3. Use the proper procedures, packaging, and bench techniques.
Follow these practices to minimize damage to static sensitive parts.
XW Warning
To prevent electric shock or personal injury. De-
energize the product and all active circuits before
opening a product enclosure, touching or handling
any PCBs or components
.
Minimize handling.
Handle static-sensitive
parts by non-conductive
edges.
Do not slide static-
sensitive components
over any surface.
When removing plug-in
assemblies, handle only
by non-conductive
edges.
Never touch open-edge
connectors except at a
static-free work station.
Keep parts in the original
containers until ready for
use.
Use static shielding
containers for handling
and transport.
Avoid plastic, vinyl, and
Styrofoam
®
in the work
area.
Handle static-sensitive
parts only at a static-
free work station.
Put shorting strips on
the edge of the
connector to help
protect installed static-
sensitive parts.
Use anti-static type
solder extraction tools
only.
Use grounded-tip
soldering irons only.

Other manuals for Fluke 87V MAX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 87V MAX and is the answer not in the manual?

Fluke 87V MAX Specifications

General IconGeneral
WaterproofYes
Product typeDigital multimeter
Product colorYellow
Frequency range0.5 - 199.99 kHz
DC voltage range0.1 - 1000 V
Resistance range0.1 - 50 Ω
Capacitance range0.1 - 9999 nF
Measuring categoryCAT III 1000V
Placement supportedHandheld multimeter
Resistance resolution0.1 Ω
Resolution (frequency)0.01 Hz
Resolution (AC current)0.1 µA
Resolution (DC voltage)0.1 mV
Temperature measurement range-200 - 1090 °C
International Protection (IP) codeIP67
Battery life800 h
Battery typeAA
Power sourceBattery
Number of batteries supported3
Weight and Dimensions IconWeight and Dimensions
Depth215 mm
Width600 mm
Height101 mm
Weight698.5 g