Do you have a question about the Fluke 975 AirMeter and is the answer not in the manual?
Temperature Range | 32 °F to 122 °F (0 °C to 50 °C) |
---|---|
CO2 Measurement Range | 0 to 5000 ppm |
Display | Backlit LCD |
Operating Temperature | 32 °F to 122 °F (0 °C to 50 °C) |
Measurement Types | Temperature, Humidity, CO2, Air Velocity, Differential Pressure |
Humidity Range | 5 % RH to 95 % RH |
Humidity Accuracy | ±2 % RH |
CO Range | 0 to 500 ppm |
Dew Point Range | -20 to 50 °C |
Wet Bulb Range | -20 to 50 °C |
Power Supply | 4 AA alkaline or rechargeable NiMH batteries |
Battery Life | Up to 10 hours |
Storage Temperature | -20 to 60 °C |
Describes the function of each softkey and pushbutton on the Meter's interface.
Explains how to power the Meter using its rechargeable battery, AC adapter, or backup AA batteries.
Details the Meter's startup sequence and the 35-second self-diagnostic test performed upon power-on.
Describes how the Meter's backlight automatically activates in low light conditions and turns off after inactivity.
Explains the Meter's auto power off feature to conserve battery life and how to configure its settings.
Outlines the five supported languages for the Meter's user interface and how to change them.
Details how to select between Metric and US measurement units for readings via the Setup menu.
Explains the Meter's clock function for logging time and date with captured readings.
Describes the CO alarm feature, its default setting, and how to adjust the threshold and notification methods.
Guides users on accessing and modifying Meter settings like time, date, units, and language.
Covers the primary measurements the Meter can take, including environmental and gas parameters.
Details the step-by-step procedure for obtaining % outside air readings using temperature measurements.
Details the step-by-step procedure for obtaining % outside air readings using CO2 measurements.
Explains how to measure air velocity and calculate volume flow rate using the optional Velocity Probe.
Describes the Min Max Avg mode for tracking minimum, maximum, and average readings for various parameters.
Introduces the Meter's capabilities for logging single-point or continuous data.
Explains how to initiate and configure continuous data logging sessions, including duration and sampling intervals.
Details the automatic and manual button lockout feature to prevent accidental input during logging sessions.
Guides users on how to retrieve and delete single-point or continuous logged data records from the Meter.
Explains how to download collected data to a PC using FlukeView® Forms software and a USB cable.
Provides instructions for calibrating the CO and CO2 sensors, either simultaneously or separately.
Details the specific steps required to calibrate the CO sensor using calibration gas.
Details the specific steps required to calibrate the CO2 sensor using calibration gas.
Provides instructions on how to properly clean the Meter's case and holster to avoid damage.
Explains how to manage the Meter's batteries and interpret the battery charge indicators displayed on startup.
Guides users on connecting the AC adapter to recharge the lithium battery and power the Meter.
Explains how to replace the AA batteries used for the Meter's backup power supply.