9103
Dry-Well
User’s Guide
March 2013
© 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
PN 2673813
1.888.475.5235info@Fluke-Direct.com
Fluke-Direct.com
Question and Answer IconNeed help?

Do you have a question about the Fluke 9103 and is the answer not in the manual?

Fluke 9103 Specifications

General IconGeneral
CategoryTest Equipment
ModelFluke 9103
DisplayLCD
Temperature Range–25 °C to 140 °C
Accuracy±0.25 °C
Resolution0.1 °C

Summary

Limited Warranty and Liability

Before You Start

Symbols Used

Lists international electrical symbols used in the manual.

Safety Information

Provides essential safety guidelines and definitions for warnings and cautions.

Authorized Service Centers

Lists authorized service centers for product support and coordination.

Introduction

Specifications and Environmental Conditions

Specifications

Details operating range, accuracy, stability, resolution, and power requirements.

Environmental Conditions

Outlines safe operating conditions including temperature, humidity, and pressure.

Quick Start

Unpacking

Instructions for unpacking the instrument and verifying components.

Setup

Guidance on placing the calibrator and connecting the power cord.

Power

Steps for plugging in and turning on the instrument.

Setting the Temperature

Procedure for setting the desired temperature set-point using front panel keys.

Parts and Controls

Back Panel

Describes the components and connectors on the rear of the calibrator.

Front Panel

Details the controller display, keypad, and button functions.

Constant Temperature Block Assembly

Explains the aluminum block assembly that provides a stable temperature environment.

Probe Sleeves

Describes the interchangeable probe sleeves for fitting various probe diameters into the well.

General

Changing Display Units

Instructions on how to switch temperature display between Celsius and Fahrenheit.

Thermal Electric Devices (TED)

Explains how TEDs are controlled to maintain constant temperature.

Controller Operation

Temperature Control and Set-point Management

Managing well temperature, set-points, units, and programmable memories.

Scan, Hold, and Switch Testing Features

Utilizing scan rate, display hold, and switch wiring for testing.

Instrument Configuration and Parameters

Accessing secondary menu, TEDs, proportional band, operating, and serial interface parameters.

Calibration Constants

Understanding and adjusting R0, ALPHA, DELTA, and BETA calibration parameters.

Digital Communication Interface

Serial Communications Setup

Configuring wiring, setup, BAUD rate, sample period, duplex mode, and linefeed.

Interface Commands and Operation

Serial operation and a list of commands for controlling the calibrator remotely.

Test Probe Calibration

Calibrating a Single Probe

Procedure for inserting a probe and comparing its temperature to the calibrator display.

Stabilization and Accuracy

Factors affecting stabilization time and achieving accuracy during calibration.

Calibration Procedure

Calibration Points and Procedure

Selecting calibration points and following the step-by-step procedure to adjust parameters.

Maintenance

Trouble Shooting

Troubleshooting Common Issues

Identifying and resolving common instrument problems and error messages.

Regulatory Compliance Information

Information regarding European directives (EMC, Low Voltage) compliance.