Changing the Length Units
MicroScanner
2
: Indicates an ID locator is
connected to the far end of the cable.
Ethernet port indicator. The speeds of the
port show under the indicator.
Wiremap diagram. The rightmost segments
indicate the shield.
The Windicates a fault or high voltage on
the cable. SPLIT appears when the fault is a
split pair.
Changing the Length Units
1
Hold down and or and while
turning on the tester.
2
Press or to switch between meters
and feet.
Auto Shutoff
The tester turns off after 10 minutes if no keys
are pressed and nothing changes at the tester’s
connectors.
Testing Cabling
1
Press to turn on the tester.
2
MicroScanner
2
: Press to switch between
twisted pair (
) and coaxial () modes.
3
Connect as shown in the following figures.
If the PoE indicator appears, see page 11.