EasyManua.ls Logo

Fluke ProcessMeter 787 Specifications

Fluke ProcessMeter 787
1 page
Page #1 background imageLoading...
Page #1 background image
Included accessories
Fluke-789 ProcessMeter:
TL71 Premium Safety-Designed
Test Lead Set plus alligator clips,
4 AA alkaline batteries (installed),
product overview and users manual
(CD-ROM) in 14 languages.
Fluke-787 ProcessMeter:
C81Y Protective Yellow Holster with
Flex-Stand, TL75 Safety-Designed
Test Lead Set plus alligator clips,
one 9V alkaline battery (installed),
product overview and users manual
(CD-ROM) in 14 languages.
Ordering information
Fluke-789 ProcessMeter
Fluke-787 ProcessMeter
Fluke 787 and 789
ProcessMeter
Test Tools
Safety rated multimeters with mA source.
Specifications – 787 and 789 ProcessMeter
Recommended accessories – 787 and 789 ProcessMeter
In-field valve positioner checks
Application Note
(Literature code 2041342)
Valve positioners open and close
with a 4-20 mA signal applied. This
application note
explains how to
adjust these
valves so they
open and close
correctly.
Measurement Function
Best Accuracy Range and Resolution (% of reading + LSD)
V dc
400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1
000 V
0.
1 % + 1
V ac (true-rms) 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.7 % + 2
mA dc 30.000 mA .05 % + 2
A dc 1.000 A (0.440 A continuous) 0.2 % + 2
A ac 1.000 A (0.440 A continuous) 1 % + 2
Resistanc
e 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M 0.2 % + 1
Frequenc
y (0.5 Hz to 20 kHz)
1
99.99 Hz, 1999.9 Hz, 19.999 kHz .005 % + 1
Diode Test 789: 2.000 V (shows diode voltage drop) 2 % + 1
787: 2.400 V (shows diode voltage drop) 2 % + 1
Continuity Beeps for resistance < approx. 100 ohms
Drive Accuracy
Output Function Range and Resolution Capability (% of span)
DC current output 0.000 to 20.000 mA or 4.000 to 20.000 mA 789: 24 V
(Internal battery operation) (selectable at power-up) Over-range to 24.000 mA compliance or, .05 %
1,200 Ohms,
@ 20 mA
787: 12 V .05 %
compliance or,
500 Ohms,
@ 20 mA
DC current simulate 0.000 to 20.000 mA or 4.000 to 20.000 mA, 1000 Ohms,
(Ext
. 24 V
olt loop supply)
(selectable at power-up) Over-range to 24.000 mA
@ 20 mA
.05 %
24 V loop supply 789: Minimum 24 V 250 Ohms > 24 V
787: not available @ 20 mA
Current adjustment modes
Manual: Coarse, Fine, 25 % and 1
00 % step (
1
00 % step 7
89 only)
Automatic: Slow Ramp, F
ast Ramp, 25 % step
Temperature range of 18 °C to 28 °C, for one year after calibration
Maximum voltage applied between any jack and earth ground:1000 V rms Storage temperature: -40 °C to 60 °C
Operating temperature: -20 °C to 55 °C Relative humidity: 95 % up to 30 °C; 75 % up to 40 °C; 45 % up to 50 °C; 35 % up to 55 °C
Safety: Designed in accordance with EN61010, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Over-voltage Category III
Size (HxWxL)/weight (787 with holster and FlexStand): 52 mm x 98 mm x 201 mm (2.06 in x 3.86 in x 7.93 in)/638 g (1.4 lbs)
Size (HxWxL)/weight (789): 50 mm x 100 mm x 203 mm (1.97 in x 3.94 in x 8.00 in)/600 g (1.3 lbs)
Fluke 789 ProcessMeter
With the Fluke 789 ProcessMeter, process technicians
can do a lot more while carrying a lot less.
Key Fluke 789 features:
24 V loop power supply
HART mode setting with loop power
(adds 250 ohm resistor)
Double-sized, dual display
20 mA drive into 1200 ohms
Backlight with two brightness settings
0-100 % mA Span Check buttons to toggle between
4 and 20 mA
Infrared I/O serial port compatible with FlukeView
®
Forms Software
Improved battery power with four AA batteries
Plus all the proven 787 features
Fluke 787 ProcessMeter
Simultaneous mA and % of scale readout on mA output
25 % Manual Step plus Auto Step and Auto Ramp on
mA output
Min/Max/Average/Hold/Relative modes
Externally accessible battery for easy changes
CAT III 1000 V safety-rated, true-rms multimeter
T
L220
8
0T
-
I
R
8
0T-150U C125 PV350
Se
e page 39
Se
e page 42
See page 43 See page 44 See page 47
For more information, go to www.MyFlukeStore.com
31

Other manuals for Fluke ProcessMeter 787

Question and Answer IconNeed help?

Do you have a question about the Fluke ProcessMeter 787 and is the answer not in the manual?

Fluke ProcessMeter 787 Specifications

General IconGeneral
DC Voltage Range0 to 1000 V
AC Voltage Range0 to 1000 V
DC Current Range0 to 20 mA
Resistance Accuracy0.2% + 1 count
Power Supply6 AA batteries
Communication InterfaceNo
Operating Temperature0 °C to 50 °C
Storage Temperature-40 °C to 60 °C
Dimensions100 x 50 mm

Related product manuals