3
© 2015 Focal Point Fires plc.
QUANTITY DESCRIPTION
1 Heater main body
1 User instruction booklet
1 Neoprene securing strip
4 Wall screws
4 Wall plugs
5.0 COMPONENT CHECKLIST
Read all the instructions before continuing to unpack or install this appliance. Carefully lift the appliance from the carton. Check
that the contents correlate with the component checklist below. Please dispose of all packaging with care at your local recycling
centre.
4.0 UNPACKING THE APPLIANCE
2.0 INSTALLATION REQUIREMENTS
3.0 APPLIANCE DATA
Supply Voltage and rating power : 220-240V AC 50Hz, 2000W Fuse Rating : 13 Amp
Heating Elements : 2 x 1000W Lighting : LED
Location : Indoor use only Supply plug/cord :BS1363/1.8 metres length
• Never immerse the product in water or any other liquids.
• DO NOT use the appliance outdoors.
• Before cleaning the appliance, ensure it is unplugged from the power and that it is com-
pletely cool.
• DO NOT clean the appliance with abrasive chemicals.
• Never use accessories that are not recommended or supplied by the manufacturer. It
could cause danger to the user or damage to the appliance.
• DO NOT insert or allow foreign objects to enter the inlet or outlet vents as this may
result in electric shock, fire or damage to the appliance.
• DO NOT install the fire using an extension cord.
• Unplug from the mains supply if the appliance is not to be used for long periods.
1.0 IMPORTANT NOTES - CONTINUED
GB IE
The appliance is suitable for installation into all proprietary surrounds with an opening of 406mm by 559mm (16” by 22”). The
appliance is supplied fitted with a spacer frame enabling it to be fitted with no need for a recess into a wall or surround back
panel. The spacer frame has a depth of 66mm. The appliance can be fully recessed if the opening depth is 66mm or greater and
no spacer is used. It may be installed directly into any proprietary surround which can house this size of rebate, without the need
to recess the appliance into a wall opening or fabricate a false chimney breast.
This appliance should be positioned on a firm level surface and in a clean ‘dust free’ environment. If the fire is to be sited in a fire
surround then the suitability of the surround for use with electrical heaters should be established with the fire surround manu-
facturer. If fitted into an open draught fireplace, it is recommended to blank off the chimney to reduce the risk of draught through
the fire, which may cause the safety cut out system in the fan heater to operate.
DO NOT
- site in a position where curtains or drapes could cover the appliance.
- site in a position where other soft materials could cover e.g. below a coat rack.
- site behind an opening door where mechanical impact/damage could occur.
- site where the supply cable would become a trip hazard.
- sit, stand or forcefully pull on the appliance.
- obstruct, cover or force items into the openings.
- use the heater to dry clothes.
- site/use in an outdoor location(s).
- run the supply cable under carpets.
- Mount on a wall.