37
E 219 GB - Issue 1
The following errors can be solved by the operator himself (these are mainly due to hitting an obstacle):
The following error codes are possible:
Error
code
Error Cause of Error Solution
11 One or both motor are
overheated
Refer to page 36.
21 Minimum speed of the
opposite column has been
too low during downward
movement
Hitting an o bstacle Press “up” key until the error code is
fully visible. The con trol switches into
stand-by mode. By pressing the “UP”
key again, the lift will move away
from the obstacle. If the vehicle is
wedged, it is possible that the motor
cannot drive free of its own accord. In
this case the control must be switched
off and driving up must be tried
again.
22 The minimum speed of the
main column has been too
low during upward
movement
Hitting an o bstacle Refer to solving error 21
23 Minimum speed of the
opposite column has been
to low during upward
movement
The load is too
heavy. Belt tension
is too slack.
Press “down” key until the error code
is fully visible. The controls switch into
stand-by mode. By pressing the
“down” key again, the drive can be
reactivated, if necessary check load
or belt te nsion.
24 The minimum speed of the
main column has been too
low during upward
movement
The load is too
heavy. The belt is
too slack.
Refer to solving error 23.