QUADRA
493 9021
493 9023
493 9031
VEHICLE LIFT
4 COLUMNS 3,5 TONNE
(AUXILIARY LIFT 3 TONNE)
Installation
Operation
Maintenance
E 167 GB
ISSUE 6 : 02/2003
English
Question and Answer IconNeed help?

Do you have a question about the FOG QUADRA 493 9021 and is the answer not in the manual?

FOG QUADRA 493 9021 Specifications

General IconGeneral
BrandFOG
ModelQUADRA 493 9021
CategoryLifting Systems
LanguageEnglish

Summary

HEALTH AND SAFETY PRECAUTIONS

SUPERSTRUCTURE ASSEMBLY

ASSEMBLY COMPONENTS

Column Anchoring Instructions

Instructions for drilling and anchoring columns using base plates as templates.

Wire Rope Installation Guide

Step-by-step guide for fitting and routing the platform suspension wire ropes.

CONNECTIONS AND FITTING

Hydraulic/Electrical Connections (493 9021)

Guides the connection of hydraulic hoses and electrical cables for model 493 9021.

HYDRAULIC/ELECTRICAL CONNECTIONS

Hydraulic/Electrical Connections (493 9031)

Guides the connection of hydraulic hoses and electrical cables for model 493 9031.

ELECTRICITY SUPPLY AND PUMP COMMISSIONING

Electricity Supply Connection

Details electrical supply requirements and connections according to IEE regulations.

Pump Commissioning Steps

Details filling the pump unit reservoir with the correct oil grade and initial checks.

ACCESSORY FITTING AND ADJUSTMENTS

Wire Rope Adjustment Procedure

Explains the necessity and procedure for adjusting wire rope tension.

COMPONENT CHECKS

Column Adjustment Verification

Verifies column squareness, centering, clearance, and verticality.

SAFETY SYSTEM CHECKS

Wire Rope Safety Switch Adjustment Check

Checks the clearance between the switch roller and the cam for safety switch function.

Obstruction/Wire Rope Failure Sensor Test

Tests the sensor's functionality by simulating an obstruction or rope failure.

VALVE CHECKS AND LUBRICATION

Ram Safety Valve Operation Test

Tests the ram safety valve's operation to stop lowering during hose failure.

AUXILIARY LIFT COMMISSIONING

OPERATION AND VEHICLE HANDLING

Operation Safety Instructions

Essential safety guidelines that must be displayed and followed during lift operation.

SAFETY VALVE AND EMERGENCY LOWERING

Lowering Platform Without Electrical Power

Manual procedure to lower the platform if electrical power is interrupted.

AUXILIARY PLATFORM EMERGENCY LOWERING

MAINTENANCE PROCEDURES

OVERLOAD TESTING

Overload Testing Requirements

Explains the requirement and procedure for dynamic and static overload tests.

FAULT FINDING AND CAUSES

REMEDIAL MEASURES FOR FAULTS

Fault Remediation Steps

Offers solutions and corrective actions for identified faults and issues.

TECHNICAL SPECIFICATIONS

Key Technical Specifications

Lists key technical specifications like load capacity, dimensions, and power.