EasyManua.ls Logo

FOG QUADRA 493 9021 - CONNECTIONS AND FITTING; Hydraulic;Electrical Connections (493 9021)

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
QUADRA
13
E 167 - GB - 6
Rue du Pré Neuf - 58440 MYENNES FRANCE
493 9021
493 9031
Fitting the ladder racks
CAUTION: UNDER NO CIRCUMSTANCES SHOULD THE LADDER RACKS BE
PAINTED. IF NECESSARY, CLEAN THEM, SCRAPE OFF ANY EXCESS RUST
AND THEN COAT WITH THICK OIL.
The top of the platform must not be more than 300mm from the ground, when fitting the ladder racks.
On each column:
Raise the wire rope sensing roller and retain in elevated position.
Insert the ladder rack into the vertical cheek plate of the cross-member.
Insert a stud bolt into the top of the column, screw a M16 locknut onto its lowest end, before
screwing it fully into the ladder rack. Then lock the nut into position.
Fit the shoulder screw through the ladder rack then into the threaded hole at the base of the
column.
Screw an M16 nut onto the top end of the bolt until the ladder rack no longer rests on the
shoulder screw at the bottom of the column, then add an M16 locknut.
Fitting the hydraulic hose and electrical connections - 493 9021
Connect the high pressure hose onto the ram, forming a large loop around the horizontal
pulleys.
Connect the oil return hose onto the ram.
Bring the coiled electrical cable into the cross-member.
Fit the conduit entry fittings at each end and fit them onto their respective brackets.
Thread the two hoses and the electrical cable through the conduit.
Attach the conduit support lug onto the track using two M8 x 16 screws with serrated lock
washers.
Connect both the high pressure hoses and oil return hose onto the power-pack.
Fix the conduit support lug onto the power-pack using a screw and serrated lock washer.
Connect the electrical cable onto the mounting plate.
Check that the circuit breaker has been set correctly as follows:
6.3 A in 400 V
10 A in 230 V
Connect the two junction boxes mounted on the cross-members, using the designated cable.